DOSAGE
52
If the SCALE is set at 255 in the “SYNCHRONIZATION” activity, when all the remote instruments dosage are
terminated, the automatic dosage starts.
For example 2:
Activity 1
Activity 2
Activity 3
Activity 1
Activity 2
Activity 3
Scale/Address
1
2
1
Parameter
SEQUENTIAL
SEQUENTIAL
Remote formual index
0
1
a) The local indicator remotely enables the selected remote formula index (index 0 for remote dosage 1,
index 1 for remote dosage 2) and transmit the set target to the remote instrument, while the remote
instruments respectively clear weight on the scale.
b) The remote dosage 1 starts to execute dosage.
NOTE: during the remote dosage, all the operations follow the relative manual of the remote instrument
which is dosing.
c) Only when the remote dosage 1 is terminated, the remote dosage 2 starts to execute dosage.
d) Only when the remote dosage 2 is terminated, the automatic dosage starts.
6.18
Example of the formula and the description of the executed cycle
Activity 1
Activity 2
Activity 3
Activity 4
TYPE
Automatic dosage
Manual dosage
Timer
Unload
FLY WEIGHT
5 KG
15 KG
5 KG
SLOW WEIGHT
5 KG
10 KG
TOLERANCE
2 KG
2 KG
2 KG
OUTPUT
1
2
3
4
PARAMETER
Not stoppable
Direct unload
In the suggested example, the instrument will execute an automatic dosage as first activity, a manual
dosage, a timer phase, and then, the total unloading of the silo. By pressing FORMULAS button in the
second page to set the formula:
Formula details
Parameters
Activities number
4
Minimum tare
2 KG
Maximum tare
6 KG
REMOTE
DOSAGE 1
REMOTE
DOSAGE 2
AUTOMATIC
DOSAGE
AUTOMATIC
DOSAGE
MANUAL
DOSAGE
TIMER
TOTAL UNLOADING