INSTALLATION
12
Figure 2. Back panel
Part
Description
1
RJ45 connector
2
Fixing for shelf or column mounting
3
Available for load cells / serial lines / inputs
/ outputs
4
Power supply input
3.2
Power supply
The indicator is powered with 12Vdc voltage (8 ÷ 36 Vdc in the IO version), through an internal adapter
which converts the 100 ÷ 240Vac, 50÷60Hz mains voltage.
To power the instrument through the 240 Vac mains insert the plug and the adapter to the 240 Vac mains
socket.
To connect the indicator to the power mains, the safety regulations must be observed, including
the use of a "clean" line without disturbances or interference caused by other electronic equipment.
Do not connect other equipment to the same socket as the one that the adapter is in.
Do not step on or crush the power supply cable.