![Dini Argeo 6116EVO Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/dini-argeo/6116evo/6116evo_user-manual_2505715006.webp)
6
Optimized layout for A4 print.
USER_MAN_ENG_6116EVO
Load cell
RS232
RS485
Analog output
50 metres with
6 x 0,25 mm
2
cable;
100 metres with
6 x 0,5 mm
2
cable.
15 m with baud rate up
to 19200.
1200 m with shielded
2 x 24 AWG twisted
pair with outer braid +
aluminium strip.
CURRENT
:
100 metres with 2 x 0,25 mm
2
cable;
150 metres with 2 x 0,5 mm
2
cable;
300 metres with 2 x 1 mm
2
cable.
VOLTAGE:
50 metres with 2 x 0,25 mm
2
cable;
75 metres with 2 x 0,5 mm
2
cable;
150 metres with 2 x 1 mm
2
cable.
RECOMMENDED DISTANCES AND CABLE CLASSIFICATION
MAXIMUM ALLOWED LENGTHS
Category I
Category II
Category III
Category IV
Distance
≥ 100 mm
≥ 200 mm
≥ 500 mm
≥ 100 mm
≥ 500 mm
≥ 500 mm
Classification
Fieldbus, LAN network
(PROFIBUS, Ethernet,
Devicenet...).
Shielded data cables
(RS232...).
Shielded cables for analog
digital signals < 25 V
(sensors, load cells...).
Low voltage power
supply cables (< 60 V).
Coaxial cables.
DC supply cables
with voltage > 60 V
and < 400 V.
AC supply cables
with voltage > 25 V
and < 400 V.
Power supply cables
with voltage > 400 V.
Telephone cables.
Any cable subject to
lightning danger.