3590ET - 3590EGT_Serial_Commands
16
BPF
BPO
BRIDGE
Description
Turns the scale buzzer acoustic device off.
Note
Works on EGT-AF01 only.
Description
Activates the scale buzzer acoustic device for no more than 10 seconds.
Note
The emitted note is LA/A (440 Hz).
Works on EGT-AF01 only.
Description
Activates a bridge between printer or AUX serial port and PC serial port.
Note
Not allowed when the instrument scale is in the DOSAGE (33) state.
The bridge connection terminates when there are no exchanged data on the serial lines for more than 10 seconds.
Format
B
P
F
Format
B
P
O
Format
B
R
I
D
G
E
p
Where
p Serial port connected to the PC serial port
Value
Description
0
PC port connected to AUX port
1
PC port connected to printer port
Example
Command
B
P
F
Answer
B
P
F
O
K
Example
Command
B
P
O
Answer
B
P
O
O
K
Example
Connects the printer serial port with the PC serial port.
Command
B
R
I
D
G
E
1
Answer
O
K
Answer
B
P
F
O
K
Answer
B
P
O
O
K
Answer
O
K