3590EKR, 3590EXP, 3590EXT, CPWE, CPWET series indicator
E-AF09_02_16.03_EN_U
48
[In which:
XXXXXX
is the acquired overall weight value]
-
At this point, it returns in the status of waiting for the input or output weighing cycle start.
13.3.2 AUTOMATIC STATIC AXLE WEIGHING
13.3.2.1 CONFIGURATION
-
Set parameter in the SETUP:
F.ModE >> totAL >> AXLE W
on
“STATIC”
.
-
If before was setted the
DYNAMIC
axles weighing, the indicator ask to set the filter of this weighing mode, press
FN/ENTER
to confirm.
-
For a correct functioning one should correctly set the weighing parameters in the
F.Mode >> total >> StA.CFG
menu of the Set-up environment or by a direct function 605, linked to a key.
(See the TECHNICAL MANUAL)
:
1.
”Min.Wei”
(minimum weigh of the axle);
2.
”Stab.tm”
(Stability interval);
3.
“tiME W”
(interval between cycles);
4.
”Skip B.”
(Beginning axles to skip);
5.
“Skip E.”
(Ending axles to skip);
6.
”Err.En”
(Axle acquisition error enable);
7.
”Tim.Out”
(Axle acquisition time out).
13.3.2.2 INPUT WEIGHING PROCEDURE
-
Select, if requested, the customer / material / vehicle to be linked to the input weigh.
-
Press the
F6
key in order to start the input weigh cycle.
-
The instrument waits for the first axle and displays:
3590E
LED display
LCD display
CPWE
[In which:
XXXXXX
is the current weight on the scale
i
means “
i
nput” weigh]
XXXXXX
ENTRY WEIGH
ENTRY WEIGH
1
CUS MAT VEH
WAITING AXLE 1 i
XXXXXX
CUS MAT VEH
WAITING AXLE 1 i
SET FILTER ?