43
Bit 15
Output relay OUT19 status
Bit 16
Output relay OUT20 status
4x0200
Output value of analog quantity (4-20mA) 2, no sign
4x0201
Last stored item
2, no sign
4x0202
Net weight of scale 1
4 bytes, signed,
read-only
4x0204
4 bytes, signed,
read-only
4x0206
Gross weight of scale 1
4 bytes, signed,
read-only
4x0208
1# analog output setting
2, no sign
4x0209
2# Analog Output Settings
2, no sign
4x0210
Current AD value of scale No.1
4 bytes, signed,
read-only
4x0212
Panel number (see Note 3 for details)
2 bytes, unsigned,
read/write
4x0213
Accumulated times of storage
2 bytes, unsigned,
read/write
4x0214
Division value
2 bytes, unsigned,
read/write
Modbus RTU function code table (continued 1)
Functional
address
meaning
Register attribute
4x0215
Low byte: weight decimal places, high
byte: flow decimal places.
2 bytes, unsigned,
read/write
4x0216
Zero range
2 bytes, unsigned,
read/write
4x0217
Zero tracking range
2 bytes, unsigned,
read/write
4x0218
IN9-IN24 (modified after 2022)
2 bytes, unsigned,
read/write
4x0219
IN25-IN40 (modified after 2022)
2 bytes, unsigned,
read/write
4x0220
Calibration coefficient of scale No.1
4 bytes, unsigned,
read/write
4x0222
Accumulated weight of stored
4 bytes, unsigned,
read/write
4x0224
Zero point calibration AD value of No.1
scale
4 bytes, unsigned,
read/write
4x0226
Maximum range
4 bytes, unsigned,
read/write