OPERATOR’S MANUAL
with Maintenance Information
Operating Instructions
47
Display Description
76
Motor Controller Left Drive Motor Fault: Check connections to the motors. Cycle power
to the lift and if that does not resolve the issue, replace the Motor Controller.
77
Motor Controller Right Drive Motor Fault: Check connections to the motors. Cycle
power to the lift and if that does not resolve the issue, replace the Motor Controller.
78
Pump Motor Short Fault: Check connections to the pump motor. Cycle power to the lift
and if that does not resolve the issue, replace the Motor Controller.
79
Left Drive Motor Short Fault: Check the Motor connections and make sure they are
tight. Check the Motor for a short.
80
Over 80% Load Warning: Platform is getting close to its limit of weight. Consider not
adding more load.
81
Right Drive Motor Short Fault: Check the Motor connections and make sure they are
tight. Check the Motor for a short.
82
Left Brake Coil Fault: Check the connections to the Coil’s terminals and make sure they
are tight. If so, check the coil itself to see if it is open or shorted.
83
Right Brake Coil Fault: Check the connections to the Coil’s terminals and make sure
they are tight. If so, check the coil itself to see if it is open or shorted.
84
Motor Post shorted: Check the connections of the controller and motor. Make sure the
wiring is not shorted.
85
Brake Release Switch On: Check the wires to brake release switch or look for a stuck
switch.
86
Brake Release Not Stowed: Check if the platform is below down limit height. Check the
down limit switch and connections.
87
Brake Release Need Switch On: Check the wires to brake release switch or look for a
Stuck switch. Check the wires to the Toggle Switch or look for a stuck Toggle Switch.
89
Motor Field Open: The field voltage is different from 1/2 battery voltage. Check
connections of the field wires or leakage to the vehicle frame.
90
Over 90% Load Warning: Platform is getting close to its limit of weight. Consider not
adding more load.
91
Left Motor Field Short: Check connections of the field wires or leakage to the vehicle
frame.
92
Right Motor Field Short: Check connections of the field wires or leakage to the vehicle
frame.
99
Over 99% Load Warning: Platform has reached its limit of weight. Do not add more
load.
OL
Overloaded Platform Fault: Remove the excess load immediately.
LL
Machine Tilted Beyond Safe Limits Fault: If the machine is tilted, find a way to make it
level. If the machine is level, check the wiring to the tilt sensor and then the sensor
itself.