![DINGLI S036-RS Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/dingli/s036-rs/s036-rs_operators-manual-with-maintenance-information_2505645057.webp)
OPERATOR’S MANUAL
with Maintenance Information
Maintenance
52
Checklist C Procedures
C-1
Test the Platform Overload System (if
equipped)
DINGLI requires that this procedure be
performed every 500 hours or six months,
whichever comes first OR when the machine
fails to lift the maximum rated load.
Testing the platform overload system regularly
is essential to safe machine operation.
Continued use of an improperly operating
platform overload system could result in the
system not sensing an overloaded platform
condition. Machine stability could be
compromised resulting in the machine tipping
over.
Perform this procedure with
the machine on a firm, level surface.
Note: Perform this test from the ground with
the platform controller. Do not stand in the
platform.
1 Turn the key switch to platform control.
Pull out the platform and ground red
Emergency Stop button to the on position.
2 Determine the maximum platform capacity.
3 Using a suitable lifting device, place an
appropriate test weight equal to the
maximum platform capacity in the center
of the platform floor.
⊙
Result: The overload alarm at the platform
controls should not sound, indicating a
normal condition.
¤
Result: The overload alarm at the platform
controls sounds. Calibrate the platform
overload system.
4 Add an additional weight to the platform
not to exceed 20% of the maximum rated
load.
⊙
Result: The overload alarm at the platform
controls sound, indicating a normal
condition.
¤
Result: The overload alarm at the platform
controls does not sound. Calibrate the
platform overload system.
5 Test all machine functions from the
platform controls.
⊙
Result: All platform control functions should
operate.
6 Turn the key switch to ground controls
7 Test all machine functions from the ground
controls
⊙
Result: All ground control functions should
not operate.
8 Lift the test weight off the platform floor
using a suitable lifting device.
⊙
Result: The overload alarm at the platform
controls should not sound, indicating a
normal condition.
¤
Result: The overload alarm at the platform
controls sounds. Calibrate the platform
overload system.
9 Test all machine functions from the ground
controls.
⊙
Result: All ground control functions should
operate.
10 Turn the key switch to platform controls.
Содержание S036-RS
Страница 3: ......
Страница 5: ......
Страница 16: ...OPERATOR S MANUAL with Maintenance Information Decals 11 ...