OPERATOR
’S MANUAL
with Maintenance Information
Maintenance
50
B-6
Test the Emergency Stop
Dingli requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
A properly functioning Emergency Stop is
essential for safe machine operation. An
improperly operating red Emergency Stop
button will fail to shut off power and stop all
machine functions, resulting in a hazardous
situation.
As a safety feature, selecting and operating
the ground controls will override the platform
controls, except the platform red Emergency
Stop button.
1 Turn the key switch to ground control and
turn the ground red Emergency Stop
button clockwise to the on position pull out
the platform red Emergency Stop button to
the on position.
2 Push in the red Emergency Stop button at
the ground controls to the off position.
⊙
Result: No machine functions should
operate.
3 Turn the key switch to platform control and
turn the ground red Emergency Stop
button clockwise to the on position pull out
the platform red Emergency Stop button to
the on position.
4 Push down the red Emergency Stop
button at the platform controls to the off
position.
⊙
Result: No machine functions should
operate.
Note: The red Emergency Stop button at the
ground controls will stop all machine operation,
even if the key switch is switched to platform
control.
B-7
Test the Automotive-style Horn
Dingli requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
A functional horn is essential to safe machine
operation. The horn is activated at the platform
controls and sounds at the ground as a
warning to ground personnel. An improperly
functioning horn will prevent the operator from
alerting ground personnel of hazards or unsafe
conditions.
1 Turn the key switch to platform control and
turn the ground red Emergency Stop
button clockwise to the on position pull out
the platform red Emergency Stop button to
the on position.
2 Push down the horn button at the platform
controls.
⊙
Result: The horn should sound.
Note: If necessary, the horn can be adjusted to
obtain the loudest volume by turning the
adjustment screw near the wire terminals on
the horn.