Code Trouble
shooting
10
System Initialization Fault: ECU may be malfunctioning, replace it.
System Communication Fault: Check communications cable connections and other
wiring. If that does not resolve the problem, try replacing the PCU or ECU.
20
System Initialization Fault: TM1 may be malfunctioning, replace it.
30
System Initialization Fault: PCU may be malfunctioning, replace it.
System Communication Fault: Check communications cable connections and other
wiring. If that does not resolve the problem, try replacing the PCU or ECU.
31
Replace PCU
32
Replace PCU
51
System Initialization Fault: ECU may be malfunctioning, replace it.
System Communication Fault: Check communications cable connections and other
wiring. If that does not resolve the problem, try replacing the PCU or ECU.
52
System Initialization Fault: PCU may be malfunctioning, replace it.
System Communication Fault: Check communications cable connections and other
wiring. If that does not resolve the problem, try replacing the PCU or ECU.
53
System Initialization Fault: TM1 may be malfunctioning, replace it.
54
Pressure Sensor Fault: Check the wiring to the sensor and then the sensor itself.
Also check to make sure that the correct option is properly selected (or not) for load
sensing
55
Angle Sensor Fault: Check the wiring to the sensor and then the sensor itself. Also
check to make sure that the correct option is properly selected (or not) for load
sensing
56
Level Sensor Fault: Check the wiring to the sensor and then the sensor itself. Also
check to make sure that the correct option is properly selected (or not) for load
sensing
57
Overloaded Platform Fault: Remove the excess load immediately
58
Pothole Guard Fault: Check that the pothole guards are extended, check the
pothole limit switches. Check wires to the switches, check the down limit switch and
connections
59
The platform touch the highest position
60
The platform touch the 2.5 m position if outdoor status
61
Machine Tilted Beyond Safe Limits Fault: If the machine is tilted, find a way to make
it level.