Capacity level sensor RFLS–35

 is designed for industrial use for limit sensing of the level of fluid and paste-like media. The 

high-frequency level sensor may be a direct replacement of a vibrating level sensor, or of a capacity level sensor in case of more 
demanding applications. The media may be electrically conductive and non-conductive with any permittivity. It can be installed in metal 
or plastic tanks, pipes, filling tanks, sumps, etc. The sensor is comprised of a stainless steel housing AISI 316L at one end terminated 
by a sensing electrode made from PEEK material, and terminated at the other end by a stainless steel ending with status indicator, 
control elements and electrical connection. It is designed for mounting into the wall of a tank or pipe, in which the actual ascertain-
ing of the level will take place. The sensor works in the high frequency band, enabling reliable detection of the level of media, and 
eliminating deposits or foam on the electrode. The sensor suppresses the influence of deposits of viscous media (ketchup, yoghurt, 
pastes, syrups, jams and jellies, creams, soap) as well as electrically conductive adhesive products (detergents, alkalis, chemicals).  

 

H

igH

-

frequency

 

limit

 

level

 

sensor

 

rfls–35

H

igH

-

frequency

 

limit

 

level

 

sensor

 

witH

 

elimination

 

of

 

deposits

 

and

 

foam

 

on

 

tHe

 

electrode

• 

Designed for reliable limit sensing of the level height  of 

wide-ranging fluids, mashed and paste-like materials 

•  Resistant to adhesion of viscous and sticky media 

(ketchup, yoghurt, spreads, syrups, creams, pastes, 
cleaning agents, alkalis, etc.)

•  Replacement of a vibrating level sensor
•  Direct mounting into tanks, vessels, sumps, pipes or 

funnels and containers

•  Settings using the magnetic pen
•  Universal design for all types of fluids (electrically 

conductive and non-conductive)

•  High stability at high sensitivity (possible to use for 

substances with 

ε

r

 ≥  1.5

)

RFLS–35_–1B

Insulated electrode (PEEK) with sealing O-ring NBR, for sensing various fluids, mashed and paste-like 
materials, appropriate also for fuel, oil or methanol, use from minimum temperature of -40°C

RFLS–35_–1E

Insulated electrode (PEEK) with sealing O-ring EPDM, for sensing various fluids, mashed and paste-
like materials, appropriate also for acids, bases or alcohol, ammonia, acetone, chlorine, from minimum 
temperature of -40°C

RFLS–35_–1V

Insulated electrode (PEEK) with sealing O-ring Viton, for sensing various fluids, mashed and paste-
like materials, appropriate also for fuel, oil, acids, bases or asphalt, tar, toluene, use from minimum 
temperature of -20°C

v