Dinamica Generale DG500 Скачать руководство пользователя страница 6

Rev

 

A1

 

Use

 

4

 

Dinamica

 

generale

 

S.p.A.

 

SECTION

 

5

 ‐ 

How

 

to

 

tare

 

the

 

scale

 

Whether

 

you

 

are

 

in

 

partial

 

or

 

total

 

weighing

 

mode,

 

you

 

need

 

to

 

zero

 

the

 

system

 

before

 

start

 

loading

  

1)

 

Press

 

 

for

 

3

 

seconds

 

until

 

you

 

see

 

the

 

message

 

“Settings

 

OK!”

 

The

 

weight

 

visualized

 

on

 

the

 

scale

 

is

 

0.

 

From

 

that

 

moment,

 

you

 

can

 

start

 

loading.

 

 

1)

 

 
 

SECTION

 

6

 ‐ 

How

 

to

 

run

 

a

 

recipe

 

1)

 

With

 

the

 

scale

 

on

 

Total

 

weight

 

mode,

 

press

,

 

select

 

the

 

recipe

 

using

 

the

 ↑↓ 

and

 

press

 

ENTER.

 

2)

 

Confirm/modify

 

number

 

of

 

animal

 

or

 

total

 

weight

 

to

 

load.

 

This

 

value

 

can

 

be

 

modified

 

using

 ↑↓

.

 

Press

 

ENTER

 

to

 

confirm.

 

3)

 

From

 

that

 

moment,

 

the

 

first

 

component

 

to

 

load

 

will

 

appear

 

on

 

the

 

display.

 

Load

 

the

 

component

 

until

 

the

 

weight

 

reaches

 

“0”

 

then

 

the

 

scale

 

go

 

automatically

 

to

 

the

 

next

 

component.

 

4)

 

At

 

the

 

end

 

of

 

the

 

load

 

of

 

the

 

last

 

component,

 

the

 

message

 

“Total

 

Loaded”

 

indicates

 

that

 

all

 

components

 

are

 

loaded.

 

The

 

countdown

 

of

 

the

 

mixing

 

time

 

starts.

  

1)

 

2)

 

 

2)

 

3)

 

 

4)

 

 

 

 
 

SECTION

 

7

 ‐ 

How

 

to

 

run

 

unloading

 

programs

 

1)

 

With

 

the

 

scale

 

on

 

Total

 

weight

 

mode,

 

press

 

 

select

 

the

 

UNLOADING

 

PROGRAM

 

using

 

↑↓ 

and

 

press

 

ENTER.

 

2)

 

Confirm/modify

 

the

 

programmed

 

“Weight

 

to

 

Unload”

  

This

 

value

 

can

 

be

 

modified

 

using

 ↑↓

.

 

Press

 

ENTER

 

to

 

confirm

 

 

 

1)

 

2)

 

 

Содержание DG500

Страница 1: ...and procedures by visiting https bit ly DG500 Man You must have an Internet connection to view the Operator s Manual As a guarantee for safe use this document does not replace the operator s manual Th...

Страница 2: ......

Страница 3: ...ndo the last change 3 Select CONTRAST from the list using and press ENTER 4 Modify the contrast using and press ENTER to confirm 1 2 3 4 Setting the unit of measure 1 Enter into the Password configura...

Страница 4: ...are working with DTM components and recipes can be created directly on PC then imported to the indicator Create Modify a component 1 Press select EDITING then COMPONENTS by pressing ENTER 2 Select the...

Страница 5: ...LOADING POINTS by pressing ENTER 2 Select the unloading point from the list then create modify it using Press ENTER to continue 3 For editing details see SECTION 2 Program Modify unloading programs 1...

Страница 6: ...or total weight to load This value can be modified using Press ENTER to confirm 3 From that moment the first component to load will appear on the display Load the component until the weight reaches 0...

Страница 7: ...e Total Unloaded will appear 3 4 SECTION 8 How to export data If you are working with the DTM you need to transfer data to the software You need a USB key or Memory Card depending on the type of your...

Страница 8: ...ect the indicator from possible water seepage Furthermore be very careful to not expose sensors junction box acoustic alarm cables or other accessories to direct water jets If the indicator needs to b...

Страница 9: ...ivered free port supplier s head office Shortcomings and defects due to the incorrect use of instruments inadequate maintenance changes carried out without the supplier s approval and normal wear are...

Страница 10: ...t den Vorschriften konform sind die in den folgenden Richtlinien FR Sont conformes aux prescriptions des directives suivantes ES Respetan las prescripciones contenidas en las siguientes directivas RU...

Страница 11: ...l support through our ticketing system 8 30 to 18 00 CET https osticket dinamicagenerale com or via e mail help dinamicagenerale com 24 7 hotline for critical breakdown support 39 346 96 55 640 or ser...

Страница 12: ...dinamica generale S p A via Mondadori 15 46025 Poggio Rusco MN Italy Cod 985 0174 Rev A1...

Отзывы: