background image

Hardware Manual  

SAFEONE DNSR-2R Time Delay Relay

11

2 Safety

Note

More detailed information can be found in the 

R

 

Technical data 

section

.

WARNING

Electric shock – dangerous voltage!

 

During operation, switching devices conduct dangerous 

voltages. 
 
Never remove protective covers from electrical switching devices during operation.

3

 

Replace the device the first time a fault occurs.

Dispose of the device in accordance with nationally applicable environmental regulations.

2.5.1

        

Retrofitting and conversion

 

•   Unauthorized conversion voids any warranty. This can cause hazards that can lead to severe  

 

     or even fatal injury.

 
2.5.2

        

Basic safety regulations

 

The safety regulations listed below must always be complied with. In the event that these safety  

 

regulations are not complied with or the device is used improperly, DINA Elektronik GmbH  

 

accepts no liability for any resulting injury or damage. 

•  The product described here has been developed to perform safety-related functions as part  
  of an entire system.
 
•  The entire system is made up of sensors, analysis units, reporting units and safe switch-off  
 concepts. 

• 

 

It is the manufacturer’s responsibility to ensure that a system or machine is functioning  

  correctly as a whole.
 
•  The manufacturer of the system is obligated to check and document the efficacy of the    
  implemented safety concept within the entire system. This documentation must be produced
   again every time the safety concept or safety parameters are modified. 

•  The manufacturer’s specifications for the system or machine with regard to maintenance    
  intervals must be complied with.
 

Содержание 33SR10

Страница 1: ...dina de SAFEONE DNSR 2R Time Delay Relay Hardware Safety switching device for enabling and time delayed enabling of control circuits...

Страница 2: ...n and translation of this documentation or parts thereof as well as the storage and processing of this content using electronic data processing systems The information contained in this documentation...

Страница 3: ...2 2 1 Electrician 8 2 2 2 Electrical designers 8 2 3 Intended use and improper use 9 2 3 1 Certification data 9 2 4 Documentation 10 2 5 Safety regulations 10 2 5 1 Retrofitting and conversion 11 2 5...

Страница 4: ...7 4 Contact outputs 19 7 5 General data 19 7 6 Connection data 20 7 7 Environmental conditions 20 7 8 Dimensions 20 7 9 Safety technical data 20 7 10 Safety related parameters in accordance with DIN...

Страница 5: ...l shock dangerous voltage Triangular symbols indicate the type of hazard in warnings Information Additional clarification Tip Additional information to help optimize the workflow 1 1 2 Emphasizing par...

Страница 6: ...value your opinion We do all we can to provide complete accurate documentation for the product If you have any suggestions for improvement or advice for us please share your thoughts with us Send us y...

Страница 7: ...truction the hazard is present during the next step 2 1 2 Design of warnings All warnings are indicated by a signal word and a warning symbol The different combinations of the signal word and warning...

Страница 8: ...oduct A specialist is a person whose specialist training means that they have the knowledge and experience includ ing knowledge of relevant regulations necessary to assess the work assigned to them an...

Страница 9: ...ained or incorrectly operated the manufacturer will not assume any liability for any damage that results In this case the risk shall be borne exclusively by the user 2 3 1 Certification data The produ...

Страница 10: ...ned instructed person who is familiar with these operating instructions and the applicable specifications regarding occupational health and safety and accident prevention WARNING Danger to persons and...

Страница 11: ...ays be complied with In the event that these safety regulations are not complied with or the device is used improperly DINA Elektronik GmbH accepts no liability for any resulting injury or damage The...

Страница 12: ...re the product is installed must correspond to the EMC section of DIN EN 60204 1 If contact outputs are used the safety function must be requested at least once per month for Performance Level e and o...

Страница 13: ...fschlugen Deutschland Produkt Product Funktion Function DNSR 2R Sicherheitsschaltger t safety switching device ID No 33SR10 33SR11 33SR12 33SR13 33SR14 Zeitrelais time relay Weitere EU Richtlinien Fur...

Страница 14: ...V DC A2 Operating voltage 0 V S11 Output control voltage 15 V S21 Output control voltage 12 V S12 Input starting circuit 1 S22 Input starting circuit 2 14 Diagnostic contact 1 NO contact 24 Diagnostic...

Страница 15: ...SR10 33SR12 37 38 1 5 s 1 5 s off delay off delay 47 48 1 5 s 50 s on delay on delay 3Open starting circuit 2 S21 S22 7Enabling contact 47 48 opens without delay 4 2 2 33SR11 3Close starting circuit 1...

Страница 16: ...es 33SR13 37 38 1 5 s on delay 47 48 180 s on delay 3Open starting circuit 2 S21 S22 7Enabling contact 47 48 opens without delay 4 2 4 33SR14 3Close starting circuit 1 S11 S12 7Enabling contact 37 38...

Страница 17: ...has an LED display indicating Operational readiness Enabling contact status 5 1 LED indicators Key LED on LED off LED flashing Contact our support team at support dina de SAFEONE DNSR 2R State LED ON...

Страница 18: ...R 2R 33SR10 33SR11 33SR12 33SR13 33SR14 7 Technical data 7 1 Supply Operating voltage UB 24V DC 10 Current consumption at 24 V 40 mA in rest position 70 mA in working position Power consumption on A1...

Страница 19: ...V DC13 at 0 1 Hz 4 A 24 V AC15 3 A 250 V Mechanical service life 107 switching cycles 5 x 107 switching cycles Contact fuse 5A gL gG Typical response release time 10ms 6 ms 7 5 General data Type of pr...

Страница 20: ...es Stripping length 8 mm Min max tightening torque 0 5Nm 0 6Nm 7 7 Environmental conditions Operating temperature 10 C to 60 C Storage temperature 40 C to 85 C Altitude of place of use 2000 m above se...

Страница 21: ...EN ISO 13849 1 2016 06 Category 1 Performance Level c MTTFd a 98 PFHd 4 3E 08 Service life 240 months 7 11 Contact life Electrical service life of the output contacts in accordance with DIN EN 60947...

Страница 22: ...756 2 953 in 1 Top hat rail 2 Locking slider 3 Cable duct Procedure 3 Hook the module onto the top hat rail and press it downward 7 The locking slider 1 engages under the top hat rail 8 2 Removing a...

Отзывы: