1. Important Notices

Read

 all information contained in this manual carefully.

Keep these instructions in a safe place and hand them
over, if applicable, to the next owner.

  The appliance is not intended for

use other than indoors, for the
heating of room air and for drying
towels, garments and similar textile
goods.

  The appliance may only be installed by an authorised

qualified electrician.

  All repairs and interventions in the appliance may

only be performed by qualified persons or the cus-
tomer service.

  The hardwired electrical installation must be provided

with an all-pole disconnecting device with a contact
gap of at least 3 mm (e.g. automatic circuit-breaker).

  For the installation of heaters in rooms with a bathtub

or a shower, it is imperative that the national electrical
codes and regulations be adhered to.

  In the event of any defect (e.g. appliance or power

cord is damaged, unit is not working), the appliance
must be disconnected from the power supply. Deacti-
vate the circuit-breaker.

 

 In the event of extended periods of non-use, the
appliance must be disconnected
from the mains power supply

.

  Do not cover the heating appliance

as there is a risk of fire!

  Do not allow appliance to be oper-

ated by children or other persons
not capable of safely using the device. Children must
be prevented from playing with or near the
appliance.

  Caution! The outside of the appliance gets hot when

in use.

  Do not insert any objects into the openings of the

appliance.

  If the supply cord of this appliance is damaged it must

be replaced by a special supply cord which is avail-
able from the manufacturer or its service agent.

   Do not use the appliance in areas where flammable

gases or liquids are stored or used.

  Caution! After the appliance has been switched on

automatically, there is a potential fire hazard as the
appliance may have been covered or obstructed prior
to switching on.

  Make sure that minimum clearances, in particular

from easily inflammable materials or heat-sensitive
plastic materials, are maintained (see Section "2.
Minimum Clearances")

  The supply cord must not be placed

over the hot appliance.

  The appliance must not be disposed in

the normal household rubbish.

2. Minimum Clearances, Mounting

The heating appliance may only be mounted and oper-
ated in vertical position on a vertical wall.
The appliance must be installed in such a way that
switches and other controls cannot be touched by the
person using the bath or the shower.
Do not mount the appliance directly under an electrical
wall outlet.
The mains socket must be accessible after the appliance
has been mounted.
It is absolutely necessary that the minimum clearances
indicated in the mounting diagram be maintained.
Beyond that, a clearance space of at least 500 mm is to
be allowed in front of the appliance.

Mounting procedure:

The heater must be fixed to the wall using 4 screws (see
diagram).
6.  Loosen left and right quick-release screws and re-

move wall bracket.

7.  Use the bracket holes to mark the holes for drilling.
8.  Drill the holes, insert the wall plugs and secure

bracket to the wall using 2 screws each at the top and
bottom.

9.  Engage heater in wall bracket.
10. Turn quick-release screws until the safety hook en-

gages the appliance back panel.

Dimensions in mm

280

200

431

167

16

A

330

46

TRFW 101

TRFW 151

TRFW 201

Dim. A 875 mm

1289 mm

1289 mm

200

150

100

100

Cable entry

Содержание TRFW 201

Страница 1: ...erh ltlich ist Ger t nicht in R umen benutzen in denen entz ndli che Gase oder Fl ssigkeiten gelagert oder verwendet werden Vorsicht Nach automatischem Einschalten des Ge r tes k nnen Gefahren entste...

Страница 2: ...gt ber 2 separate Heizsysteme a W rmewellenheizung mit W rmeabgabe ber die beheizte Oberfl che b L fter Warmluft W rmeabgabe erfolgt durch einen L fter mit separatem Heizelement ber die Luftaus lasssc...

Страница 3: ...L fter wieder be triebsbereit Nach Beseitigung der Ursache f r das Ausl sen des berhitzungsschutzes z B Luftschlitze abgedeckt kann das Ger t wieder in Betrieb genommen werden Sollte der berhitzungss...

Страница 4: ...tten die entsprechenden VDE Vorschriften die Bestimmungen der rtlichen Versorgungsunternehmen oder unsere Montage und Gebrauchsanweisung nicht beachtet worden sind Durch etwa seitens des Endab nehmers...

Страница 5: ...e replaced by a special supply cord which is avail able from the manufacturer or its service agent Do not use the appliance in areas where flammable gases or liquids are stored or used Caution After t...

Страница 6: ...ion The heater has 2 separate heating modes a Radiant heating via the heated surface b Hot air fan heater The heat is given off by a fan with a separate heating element via the air outlet slots provid...

Страница 7: ...t protection has been eliminated e g air slots are covered the appliance can be restarted Should the overheat protection trip repeatedly please consult your customer service agent 8 Malfunctions In th...

Страница 8: ...Dimplex Deutschland GmbH Phone 49 0 9221 709 564 Subject to technical changes Am Goldenen Feld 18 Fax 49 0 9221 709 565 D 95326 Kulmbach E Mail kundendienst hauswaerme glendimplex de Internet www dimp...

Отзывы: