Dimplex SmartRad fan convector 

Models: SRX 80, SRX 120, SRX 140 & SRX 180 

PLEASE STORE THESE INSTRUCTIONS IN A SAFE PLACE. 

 

 

Important safety information  

The  air  inlet  and  outlet  guards  must  not  be  covered  or 
blocked.  
Before  performing  maintenance  work  on  the  device,  discon-
nect it from the power supply. 
THE DEVICE MUST BE GROUNDED. 
The heater must not be installed directly below a permanently 
installed  socket.  Combustible  materials  or  liquids  and  other 
highly  flammable  furnishings  must  be  kept  away  from  the 
heater.  
For the necessary minimum distances (in mm), see fig. 4. 
Install  the  device  such  that  it  is  not  possible  for  someone  in 
the bath or shower to touch the control elements.  
The heater must not be operated in very dusty areas. 
This device is not suitable for children or persons who cannot 
use the device safely as a result of physical or mental disability 
or  reduced  perception  without  the  assistance  or  supervision 
of  another  person.  Children  should  be  supervised  to  ensure 
they do not play with the device. 

A warning symbol is attached to the heater. This in-
dicates that the device must not be covered. 
The operating instructions belong to the device and 

must be stored in a safe place. If the owner changes, the op-
erating instructions should be passed on to the new owner. 
IMPORTANT – If the mains cable of the device is damaged, it 
must  be  replaced  by  the  manufacturer,  a  customer  service 
representative or a similarly qualified person. 
Always ensure proper operation. 

 

Device description 

The SmartRad model is a fan convector for heating living spaces. 
The fan convector is intended for connection to a central heat-
ing system. The fan convector is suitable for use in heat pump 
systems, but it can also be operated in conjunction with other 
heating systems, e.g. with oil or gas fires. The device draws in air 
from the underside. This is heated up in the heat exchanger and 
discharged at the top. 

Fig. 1:  
(a) Casing cover 
(b) Control panel 
(c) Air outlet guard 
(d) 1 m connection cable 

Fan  convectors  may  only  be  used  in  central  heating  systems 
with a closed control circuit. 
The heating system must be operated as a dual-pipe system. 
The  devices  must  be  of  a  sufficient  rating  such  that  they  can 
compensate for heat losses in the room.  

Technical data 

 

 

SRX 80 

SRX 120 

SRX 140 

SRX 180 

Heat output (kW) at  

flow temperature of 

45°C 

0.70 

1.10 

1.40 

1.80 

Temperature range  

of flow temperature (°C) 

 

25 – 85 

Maximum permissible  

flow temperature (°C) 

 

85 

Permissible operating 

overpressure (MPa) 

 

Pressure drop (kPa) 

 

11.3 

13.1 

13.7 

15.8 

Air volume flow (m³/h) 

228 

345 

410 

540 

125 

190 

225 

300 

60 

100 

120 

160 

Sound pressure level at 

1 m (dB(A)) 

47 

38 

27 

Nominal voltage 

 

~ 230 V, 50 Hz 

Power consumption  

of fan (W) 

26 

43 

56 

50 

19 

29 

36 

33 

16 

20 

24 

23 

Standby energy 

consumption (W) 

 

< 1 

Protection category 

 

IP 20 

Volume of  

heat exchanger (ml) 

 

310 

430 

480 

600 

Dimensions 

W x H x D (mm) 

 

503 x 
530 x 

145 

670 x 
530 x 

145 

740 x 
530 x 

145 

911 x 
530 x 

145 

Weight (kg) 

 

12 

15 

17.5 

22 

 

Installation preparation 

Remove packaging material.  
Unscrew  the  four  fixing  screws  from  underside  of  device  (see 
fig.  2)  to  remove  casing  cover.  Store  casing  cover  such  that  it 
cannot be damaged during installation. 
 

Fixing to the wall 

For drywalls, use suitable fixing material (not supplied)! 
Draw and drill four holes on a sturdy wall as shown in fig. 4. All 
dimensions are in mm. 
Insert dowels and pre-fit the two top screws (don't completely 
screw in yet).  
Hang device on the two top screws.  
Insert and tighten the two bottom screws, then tighten the two 
top screws.  
 

Hydraulic connection 

To ensure a sufficient heating water flow rate through the fan 
convectors, observe the following points: 

-

 

The  devices  are  not  suitable  for  installation  in  single-pipe 
systems. 

-

 

The  nominal  width  of  the  connection  pipe  must  have  a 
minimum diameter of 15 mm. 

-

 

If the devices are installed in a heating system with various 
heat  distribution  systems  (e.g.  underfloor  heating),  a  sepa-
rate circuit is required to guarantee a sufficient  water  flow 
rate. 

-

 

For optimum operation (heat output) of the fan convectors, 

EN 

Содержание SRX 080M

Страница 1: ...The product complies with the European Safety Standards EN60335 1 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC DE EN srx_en de_ba 12 10 A ...

Страница 2: ... 30 125 MIN 590 MIN 535 150 MIN 150 MIN 235 MIN 100 MIN a d b c J A E B F C G D H K 1 2 3 4 82 A B C D SRX 080 503 324 396 386 SRX 120 670 492 564 564 SRX 140 740 562 634 624 SRX 180 911 732 804 794 50 15 150 50 220 ...

Страница 3: ...P N L1 P N L1 5 6 ...

Страница 4: ... 1063 1378 1 411 691 955 1251 3 806 1394 2016 2668 3 689 1164 1557 2070 2 591 1010 1447 1894 2 530 894 1215 1606 1 379 641 907 1174 1 357 599 828 1083 3 587 1012 1460 1926 3 530 902 1190 1580 2 413 704 1005 1309 2 387 655 884 1163 1 237 399 564 728 1 231 387 534 694 35 C 45 C 55 C 65 C 35 30 C 45 40 C 55 47 C 65 50 C 3 551 918 1284 1649 3 1495 2856 3925 4628 2 487 812 1136 1460 2 893 1760 2424 287...

Страница 5: ...Casing cover b Control panel c Air outlet guard d 1 m connection cable Fan convectors may only be used in central heating systems with a closed control circuit The heating system must be operated as a dual pipe system The devices must be of a sufficient rating such that they can compensate for heat losses in the room Technical data SRX 80 SRX 120 SRX 140 SRX 180 Heat output kW at flow temperature ...

Страница 6: ...e forwarded to any downstream devices via the control conductor see fig 6 on the right The control conductor does not have to be in phase with the supply connection If the control conductor is not used it must be properly insulated WARNING if you switch over to controlled operation the mains voltage is on this conductor WARNING do not ground the control conductor When taking out of service e g for...

Страница 7: ...w temperature higher on heating system Insufficient water flow rate through device Adjust flow rate hydraulic balance To do this close ther mostat valves on the other heaters Dirt on heat exchanger Clean heat exchanger see Maintenance section Cleaning outer surfaces The heater must be switched off and cooled for cleaning The surfaces of the heater can be cleaned by wiping with a soft damp cloth an...

Страница 8: ...erden Das Gerät saugt auf der Unterseite Luft an Diese wird im Wärmetauscher erwärmt und nach oben ausgeblasen Abb 1 a Gehäuseabdeckung b Bedienfeld c Luftaustrittsgitter d Anschlussleitung 1 m Die Gebläsekonvektoren dürfen nur in Zentralheizungsanlagen mit geschlossenem Regelkreis verwendet werden Die Heizungsanlage muss als Zweirohrsystem ausgeführt sein Die Geräte müssen ausreichend dimensionie...

Страница 9: ...tete Geräte weitergegeben Betrieb mit Programmierkassette Die Steuersignale der im Pilotgerät eingesteckten Programmier kassette werden über den Steuerleiter an eventuell nachge schaltete Geräte weitergegeben siehe Abb 6 rechts Der Steuerleiter muss nicht phasengleich zum Netzanschluss sein Wird der Steuerleiter nicht verwendet muss dieser fachge recht isoliert werden ACHTUNG beim Umschalten auf g...

Страница 10: ...reichender Wasserdurchfluss durch das Gerät Durchflussmenge einstellen hydraulischer Abgleich Hier für die Thermostatventile an den weiteren Heizkörpern zu drehen Schmutzablagerungen am Wärmetauscher Wärmetauscher reinigen siehe Abschnitt Wartung Außenflächen reinigen Zur Reinigung muss das Heizgerät ausgeschaltet und abgekühlt sein Die Oberflächen des Heizgerätes können durch Abwischen mit einem ...

Отзывы: