73
730.138 | 08.1
EN
Differential thermostat:
Factory
setting
Adjustable
down to min.
Adjustable
up to max.
Comment
Temperature controlled:
Switch-on temperature difference:
6 K
Switch-off
temperature
diff K
80 K
Switch-off temperature difference:
3 K
0 K
Switch-on
temperature dif-
ference - K
Maximum heat source temperature:
100 °C
Minimum
source tem-
pe K
180 °C
Minimum heat source temperature:
0 °C
0 °C
Maximum
source tempera-
ture - K
Temperature limit heat target:
60 °C
0 °C
95 °C
Time controlled:
--
00.00
3.59
Programming a time period which goes beyond
midnight (4.00) is not possible.
Time function:
Factory
setting
Adjustable
down to min.
Adjustable
up to max.
Comment
Time controlled:
--
00.00
3.59
Programming a time period which goes beyond
midnight (4.00) is not possible.
Содержание SOLCU
Страница 75: ...75 730 138 08 12 EN 14 Notes ...
Страница 76: ...730138 ...