70
730.138 | 08.1
EN
13.3 Parameter values for functions
Circulation:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Time controlled:
-
00.00
3.59
Programming a time period which goes beyond
midnight (4.00) is not possible.
Temperature controlled:
Switch-on temperature:
30 °C
0 °C
Switch-off
temperature - K
Switch-off temperature:
35 °C
Switch-on
temperature
+ K
95 °C
Pulse controlled:
Circulation time:
min
1 min
10 min
Wait time:
10 min
0 min
60 min
Back-up heating
:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Temperature controlled:
Switch-on temperature:
55 °C
0 °C
Switch-off tem-
perature - K
Switch-off temperature:
60 °C
Switch-on
temperature
+ K
95 °C
Time controlled:
--
00.00
3.59
Programming a time period which goes beyond
midnight (4.00) is not possible.