Dimplex SELBORNE 5 SE Скачать руководство пользователя страница 5

 

 

Fig. 4 – Arranging the flue outlet blanking plug for top or rear outlet 

Fig. 5 – Operating your stove 

Top flue outlet collar 

Rear flue collar 

Flue outlet blanking plate gasket 

Flue outlet blanking plug 

Heat shield 

Airwash control (secondary air) 
Push to decrease air flow (close) 
Pull to increase air flow (open) 

Primary air control 
Slide left to close 
and right to open 

Opening the door 

Note:  As  the  handles 
become  hot  in  use  it  is 
recommended  that  you 
use 

the 

stove 

mitt 

supplied. 

 

OPERATING INSTRUCTIONS 

WOODBURNING 

 
 
 
 
Fig. 5 shows stove and its controls. 

Additional loose parts supplied inside your stove include: 

 

A stove mitt – for removing the ash pan, adjusting the primary air controls, adjusting the airwash control, 

and operating the door handle. Fig.5 shows how the stove mitt is used. 

 

A flue blanking plug to blank the top flue outlet if the rear flue outlet is to be used. 

 
 

 

 

 

Before lightning the fire for the first time ensure that the baffle, side and back bricks and all the internal components 

are in position. Burning without either will result in the stove overheating and being damaged. 

 

Open the air wash control and the primary air control fully. Place some tightly rolled paper on top of some crumpled 

paper on the base towards the back of the stove. On top of this, place some small pieces of wood. Light the crumpled 

paper and close the door. Once the fire becomes established add some larger pieces of wood. As the stove comes up 

to temperature close the primary air control using the stove mitt as shown in Fig.5. The burning rate of the stove can 

now be regulated by the rate at which fuel is added and by adjusting the air wash control. 

 

With the above in mind it is plain to see that the stove should ideally be run with the primary air inlet closed and the 

air wash control open whenever possible. Another advantage of running the stove with the air wash open is that the 

air  is being  drawn  into  the  stove  travels  across  the  glass  forming  an  air  barrier  between  the  glass  and  the  fire  bed 

helping to prevent smoke particle sticking to the glass. 

 

If the fire dies down too low, opening the primary air control for a short period will revive it. When reviving a low 

fire  it  is  important  to  also  use  kindling  before  adding  larger  logs  to  help  prevent  smoke. 

 

 

 

 

 

 

 

 

 
 
 

Only remove small amounts of ash from the firebox. When de-ashing, leave 30-40mm depth of ash in the bottom of 

the firebox for the best performance. Always use the stove mitt to open and close the door. 

YOUR STOVE 

LIGHTING & CONTROLLING THE FIRE 

Note:  Wood  burns  most  efficiently  when  the  air  for  combustion  is  supplied  from  above  the  fire  bed  rather  than 

below. The air supplied above the fire bed provides the oxygen necessary for the volatile gases (smoke), given off 

by the wood as it heats to combust. This ensures that the gases are burnt and used to heat the stove instead of being 

wasted up the chimney or condensing and forming tarry deposits inside the stove, in the flue or on the stove glass. 

Running the stove with the primary air control open and the air wash control closed  will provide oxygen for  the 

wood to burn on the fire bed but will not provide air for the volatile gases above the fire bed to combust resulting 

in a smoky inefficient fire.

 

ASH REMOVAL 

Содержание SELBORNE 5 SE

Страница 1: ...may be of use to you and is available 24 hours a day It includes Operating and installation instructions Easy How to use guides for storage heaters Service and repairs Where to buy our products Liter...

Страница 2: ...at output Refer to Building Regulations Document J a purpose provided air vent is not normally required However in certain circumstances a purpose provided air vent may be necessary for example small...

Страница 3: ...d fuel Be a minimum 4 6m high from hearth level to pot Be terminated at least 1m above roof level so that the chimney does not terminate in a pressure zone see Fig 2 Be free from cracks severe bends v...

Страница 4: ...This test is only a guide as an apparently poor flue may improve once the stove is installed lit and the flue is warmed If once the stove is installed there is any doubt that the chimney is providing...

Страница 5: ...5 The burning rate of the stove can now be regulated by the rate at which fuel is added and by adjusting the air wash control With the above in mind it is plain to see that the stove should ideally be...

Страница 6: ...ignites may cause a chimney fire Resinous softwood burns well and gives a high output for short periods but is not as efficient and does not last as long as hardwood CORRECT RUNNING TEMPERATURE FOR B...

Страница 7: ...must be presented The guarantee is 1 year from date of purchase The guarantee does not cover parts that are deemed to be replacable through normal usage of the stove These include glass panels rope s...