Installation, Operation &  

Maintenance Instructions

Forced Air Heater

Series “D” RFV-800

Remove heater from carton.  The front grill and trim can 

be lifted off assembly, and placed in carton to prevent 

damage.  Remove screws securing heater assembly to 

the recess box and separate (Fig. 1).

NOte:

  Mount the heater a minimum of 12 inches (30.5 

cm) from the finished floor.

Recessed Installation

1.  The recess box provided with the heater is designed  

  for attachment between studs placed on 16” (40.6cm)  

  centres.  If different spacing exists, construct frame  

  to suit the box in order to avoid any vibration and  

  noise caused by loose mounting (Fig. 2a).
2.  Note orientation of box (“TOP” shown on recess box)  

  and secure to studs using four holes provided on side  

  flanges, ensuring these flanges are flush with 

 

 

finished surface

 of wall (Fig. 2b).

Surface Installation

1.  Secure optional surface mount box (Part No. RFP8D)  

  by angling screws through holes provided in rear of  

  surface box into studs or finished surface.

2.  Position recess box into surface box and secure with  

  four screws provided in parts bag of surface box.

Fig. 1

Ground

Screw

Front Panel (Grill)

& Trim Frame

Heater

Assembly

Recess Box

Fig. 2

19 3/4”

(50 cm)

MIN. 12”

(30.5 cm)

14 1/4”

(36 cm)

(a)

(b)

Side  

Flanges

15”

(38 cm)

Finished Wall

Surface

7/8” (22 mm) Dia. 

Knockout

14 1/4”

(36 cm)

19 3/4”

(50 cm)

3 5/8”

(9 cm)

Finished 

Floor

MIN. 12”

(30.5 cm)

NOte:

 Dimensions are shown as 

size of rough opening in stud wall