background image

Supply Wiring and Heater Installation

1.  Insert approximately 15” (38cm) of supply wire into recess box  

  through knockout provided in upper left hand corner (Fig. 2b).
  Wire should be rated for a minimum of 75°C (167°F)
2.  Connect power supply to terminals provided marked L1 and L2.  

  Ground wire should be secured to green ground screw provided  

  on side of heater assembly (Fig. 1).
3.  All units are factory prewired for operation with built-in thermostat.  

  If remote thermostat operation is required follow appropriate  

  wiring diagram located on inside of recess box.

NOte:

  All wiring must comply with National Electrical Code and  

local codes.

4.  Secure heater assembly to recess box using four (4) M4 screws  

  removed at the start of these instructions.  

Front Panel Installation

1.  Remove trim frame from front panel assembly.
2.  If tamperproof built-in or remote thermostat operation is required,  

  secure the louvered door to the front panel using two (2) M3  

  screws (not included) through the holes provided.  The knob can  

  then be removed and adjustment of the thermostat can be made using a slotted screwdriver through the front  

  panel.
3.  Check to see that the fan blade is free to turn and that no residue remains in the unit.  Front panel can then  

  be secured to assembly using four (4) M4.8 x 37 screws provided.
4.  Follow the steps in Fig. 3.

Operation and Maintenance

1.  Set thermostat to desired temperature and both fan and heat should come on.  Note that when desired  

  temperature is reached the fan operation will continue for a short period after the elements have de- 

  energized in order to remove residual heat from the unit.
2.  The fan motor is permanently lubricated and sealed at the factory and is maintenance free.
3.  It is suggested that at the beginning of each season the front panel is removed and the wire connection  

  condition is checked and the unit is cleaned of dust and dirt with a vacuum cleaner.

NOte:

  Always open the circuit breaker to disconnect power to the unit prior to performing any maintenance or 

service operation.

WARNING:

  Should the Over Temp light come on, disconnect power to the heater or turn down the thermostat 

fully counterclockwise and call a licenced electrician.  DO NOT USE HEATER UNTIL PROBLEM IS

DETERMINED AND FIXED. 

CATALOGUE NO.

MOTOR

CAPACITOR

FAN BLADE

ELEMENT

CUT-OUT

FAN DELAY THERMOSTAT FRONT PANEL KIT

RFV831551

RFVFPA

RFV831551W

RFVFPW

RFV831581

RFVFPA

RFV831581W

RFVFPW

RFV842051

RFVFPA

RFV842051W

RFVFPW

RFV842081

RFVFPA

RFV842081W

RFVFPW

2600060400RP

16210094RP

00029001RP

3200070100RP

REPLACEMENT PART

2000260100RP

00010034RP

16210091RP

00009114RP

00033002RP

2600060400RP

16210093RP

00029001RP

16210092RP

Fig. 3

A

B

C

C

(A)  Place frame over top of tabs.

(B)  Push in at bottom until frame is flush  

       with front panel.
(C)  Insert two (2) screws to hold frame in   

       place.