background image

7200610100R13

Forced Air Heater

RFI-D Series

 WARNING: 

Wiring procedures and connections should be 

in accordance with the National Electric code (NEC & CEC) 

and local codes.

 WARNING: 

To reduce the risk of fire, do not store or use 

gasoline or other flammable vapors or liquids in the vicinity of 

the heater.

 CAUTION:

  High  temperature,  risk  of  fire,  keep  electrical 

cords, drapery, furnishings, and other combustibles at least 

3 feet (0.9 m) from the front of the heater.

Remove heater from carton. The front grille and trim can be 

lifted off the assembly, and placed in carton to prevent dam

-

age. Remove screws securing heater assembly to the recess 

box and separate. (Figure 1).

!

 NOTE:

 Mount the heater a minimum of 12” (30.5cm) from 

the finished floor, and a minimum of 6” (15cm) from any verti

-

cal surface if installed in the ceiling.

Recessed Installation

1. 

The recess box provided with the heater is designed for 

attachment between studs placed on 16” (40.6cm) cen

-

 Installation Instructions

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions should al

-

ways be followed to reduce the risk of fire, electric shock, and 

injury to persons, including the following:

1.  Read all instructions before using the heater.
2. 

The heater is hot when in use. To avoid burns, do not let 

bare skin touch hot surfaces. The trim around the heater 

outlet becomes hot during heater operation. Keep com

-

bustible materials, such as furniture, pillows, bedding, pa

-

pers, clothes, and curtains at least 3 ft (0.9 m) from the 

front of the unit and keep them away from the sides and 

rear.

3. 

Extreme caution is necessary when any heater is used by 

or near children or invalids and whenever the unit is left 

operating and unattended.

4.  Do not operate any heater after it malfunctions. Discon

-

nect power at the service panel and have the heater in

-

spected by a reputable electrician before reusing.

5. 

Do not use outdoors.

6. 

To  disconnect  the  unit,  turn  the  controls  off,  and  then 

switch off at main power supply panel.

7. 

Do not insert or allow foreign objects to enter any venti

-

lation or exhaust opening as this may cause an electric 

shock or fire, or damage to the heater.

8. 

To prevent a possible fire, do not block air intake or ex

-

haust in any manner.

9. 

All electrical heaters have hot and arcing or sparking parts 

inside. Do not use in areas where gasoline, paint, or flam

-

mable liquids are used or stored.

10. 

Do not modify this heater. Use it only as described in this 

manual. Any other use not recommended by the manufac

-

turer may cause fire, electric shock or injury to persons.

SAVE THESE INSTRUCTIONS

Figure 1

FRONT PANEL

(GRILLE) & TRIM FRAME

GROUND

SCREW

HEATER

ASSEMBLY

RECESS BOX

FINISHED WALL

SURFACE

SIDE FLANGES

15"

[38cm]

min. 12"

[30.5cm]

3 5/8"

[9cm]

14 1/4"

[36cm]

  19 3/4"

  [50cm]

7/8"[22mm] DIA

KNOCKOUT

FINISH FLOOR

  19 3/4"

  [50cm]

14 1/4"

[36cm]

min. 12"

[30.5cm]

Figure 2

A

B

Содержание RFI-D Series

Страница 1: ...nd the heater outlet becomes hot during heater operation Keep com bustible materials such as furniture pillows bedding pa pers clothes and curtains at least 3 ft 0 9 m from the front of the unit and k...

Страница 2: ...es provided on side flanges ensuring these flanges are flush with finished surface of wall or ceiling Figure 2b Surface Installation 1 Secure optional surface mount box Part No RFP8D by angling screws...

Страница 3: ...warranty claim without the Manufacturer s authorization This Warranty is transferable by the original consumer purchaser of the product Any claims under this Warranty must be submitted in writing to t...

Страница 4: ...s chaudes La bordure autour de la bouche de chaleur devient chaude lorsque le radiateur fonctionne Garder tout mat riel combustible comme des meubles des oreillers de la literie du papier des v te men...

Страница 5: ...du plafond Figure 2b Installation du radiateur en surface 1 Fixez le bo tier d installation en surface optionnel pi ce n RFP8D en alignant les vis dans les trous situ s l arri re du bo tier de surface...

Страница 6: ...t au chef du service d entretien Dimplex North Ame rica Ltd 1367 Industrial Rd Cambridge Ontario N3H 4W3 Canada AVERTISSEMENT Ce radiateur lectrique doit tre install correctement avant son utilisation...

Страница 7: ...al menos 3 pies 0 9 m de la parte delantera del aparato y alejados de los laterales y de la parte trasera 3 Hay que extremar la precauci n cuando se use cualquier ca lentador de aire cerca de los ni...

Страница 8: ...distinta construya un marco adaptado al armaz n para eliminar todo ruido o vibraci n causado por una instalaci n inestable Figura 2a 2 Ubique correctamente el armaz n con la palabra TOP ARRIBA en la p...

Страница 9: ...esentadas por escrito al Gerente de Servicio Dimplex Am rica del Norte SA 1367 Rd Industrial Cambridge Ontario N3H 4W3 Canad ADVERTENCIA Debe instalar el calentador de aire de manera adecuada antes de...

Отзывы: