- 17 -
Product Locks
Product Locks are methods of locking the heater’s controller to restrict access to functions. This can be activated and
confi gured via the Settings Menu. When Product Lock is activated, the heater continues to run in whichever mode is
currently active and any/all wireless communications remain active if enabled.
Child Lock
This is the simplest locking method and does not utilise a PIN code. It is toggled on/off on the heater’s controller by
pressing and holding the
Back
button and the
Dial
for three seconds.
While Child Lock is active, the heater will continue to operate in whatever mode, with whatever settings it had before
the lock was activated.
There are no exception rules with this lock, and the user can only choose to unlock the heater if they wish to change
the temperature, modes or settings.
Heater Lock (PIN Lock)
Heater Lock is the most customisable and secure lock on the heater. This allows the heater to be confi gured in any way,
then locked into those settings and modes.
When PIN Lock is activated, pressing the
Menu
button will show one item* that can be selected - ‘Unlock’. Selecting
‘Unlock’ prompts the User to complete the applicable Unlock action:
Menu
Unlock
PIN Lock
123-
Enter 4 Digit
PIN
PIN Unlocked
*Unless Boost Mode has been
enabled during UI Lock
Manual
PIN Lock Exceptions
It is possible to allow the ‘Advance’ and ‘Boost’ functions to be enabled/disabled when PIN Lock is active.
There are up to 4 exceptions. These exceptions include:
-
Advance
• Ability to activate using the ‘Advance Button’
-
Boost
• Ability to activate using the ‘hotkey’ listed in the Main Menu
• Ability to modify the Boost Temperature
• Ability to modify the Boost Duration
‘Advance Function’ Operation during PIN Lock
If Advance has been enabled during PIN Lock, the Advance button will remain active when PIN Lock is active. This will
function in the same way it would if the controls were not locked: only if the Heater is Locked into a Timer Mode.
• If Advance is enabled during UI lock, the
Advance
button will function as normal while the Heater is set to a Timer Mode.
• If Advance is Disabled during UI lock, the
Advance
button will not function.
‘Boost Function’ Operation during PIN Lock
If enabled, Boost will function in the same way as it does when PIN Lock is not active unless modifi cation of Boost
Temperature and Boost Duration have been disabled.
Boost Temperature and Boost Duration will be set to the default values when ‘Boost’ is activated. If either of these values
have been disabled during Product lock, when the user tries to modify them the heater’s display will show the message
‘Disabled’ and only the default value can be used. The default values can be changed outside of PIN Lock.