background image

 

4

Installation and Operating Instructions

 

 

PLX 050 – 300, PLX 050 TI – 200 TI   Convector Heater

 

453321.66.53gb  

 

02/03/A

 

 

1. Warnings 

You are requested to read carefully all the information in 
these instructions. Keep these instructions carefully and if 
applicable pass them on to the final owner. 
 

If the appliance is damaged, check immediately with 

the supplier before installation. 

The appliance should be installed and repaired by a 

qualified electrician. 

In the event of a fault disconnect the electricity supply 

to the appliance by switching off or removing the fuse. 

Where the appliance is out of operation for a long 

period, disconnect the electricity supply to the 
appliance. 

This appliance is only suitable for domestic use or 

similar purposes within enclosed spaces. 

During installation of the appliance, the relevant 

requirements for the connection of supply cords with a 
nominal voltage up to 1000V, are to be followed. 

Do not use materials in the room where the appliance 

is installed whose fumes or the material itself could 
give rise to ignition, explosion or thermal 
decomposition due to the high temperatures. In such 
cases (e.g. the sticking down of floor coverings) 
ensure that the appliance has cooled down to room 
temperature. 

The surfaces, especially the grille, become hot during 

operation. 

Do not insert objects through the openings of the 

appliance. This could lead to functional faults, possibly 
to the ignition of the object. 

Dismounting of the appliance and disconnection from 

the mains should only be carried out by a competent 
electrician. 

Warning! There may be dangers following the 

automatic switching on of connected heaters in your 
absence, e.g. heaters which have been moved or 
covered in the meantime could cause a fire. 

 

2. Mounting, minimum clearances 

The convectors must only be installed horizontally. They 
are to be installed so that flammable obstructions cannot 
be ignited. The heater may be mounted on a wooden wall. 
The heater must not be located below a fixed socket-outlet. 
The minimum clearances, A, B and C, particularly to easily 
combustible objects such as curtains, upholstered furniture 
etc must be observed. Ensure that the air can circulate 
freely around the heater. 
The heater must only be installed using the wall brackets 
supplied. 

Drill the fixing holes for the wall bracket. 

Screw the bracket securely to the wall. 

Present the heater to the wall bracket and engage the 

slots in the back of the heater. 

 

3. Electrical connection 

If the power supply cord of this appliance is damaged, it 
must only be replaced with a cord supplied by an 
authorised Service Agent. 
The heater models PLX 250 and PLX 300 are fitted with a 
supply cord without a plug. The supply cord must be 
connected to a suitable connection box. 
 

4. Cleaning the appliance 

Before commencing cleaning switch 
off the heater and allow to cool. 
Release locking and hinge forward. 
The outside can be cleaned by 
wiping it over with a soft damp cloth 
and then dried.  
Do not use abrasive cleaning 
powders or furniture polish, as this 
can damage the surface finish. 
 
 

5. Heater operation 

5.1 Heaters PLX 075 to PLX 200 

The controls are located on the front of the heater and 
protected with a lockable cover. The cover can be opened 
with a screwdriver by turning the slot anti-clockwise. Close 
the cover again after adjusting the controls. 

 Lock 

Important! The cover should always be kept closed except 
when adjusting the controls. 

5.2 Heaters PLX 250 and PLX 300. 

The controls on these heaters are located on the right 
hand side. 

GB 

250

 

 A

 

 B

 

  C

 

Minimum clearances 
A, B, C: 150mm 

Содержание PLX 050/TI

Страница 1: ...1 Montage und Gebrauchsanweisung Instructions for use Instructions de fonctionnement PLX 050 TI PLX 200 TI PLX 250 PLX 300 Wandkonvektor Convector Heater Convecteur de Base Mural...

Страница 2: ...telbar unterhalb einer Steckdose montiert werden Die Mindestabst nde A B und C insbesondere zu leicht brennbaren Gegenst nden wie Vorh nge Polsterm bel usw d rfen nicht unterschritten werden Bitte ach...

Страница 3: ...des Luftgitters so schaltet das Ger t automatisch ab 6 1 PLX 050 TI bis PLX 200 TI Zur Wiederinbetriebnahme des Ger tes beseitigen Sie die Ursachen f r das Ansprechen des berhitzungsschutzes Gleichze...

Страница 4: ...h have been moved or covered in the meantime could cause a fire 2 Mounting minimum clearances The convectors must only be installed horizontally They are to be installed so that flammable obstructions...

Страница 5: ...t out For your safety the convector is fitted with a thermal cut out If the air circulation is restricted e g hanging something over or blocking the air outlet grille the heater will switch off automa...

Страница 6: ...inimales Les convecteurs ne peuvent tre install s que verticalement Il faut viter que les objets inflammables prennent feu Il est possible de monter le convecteur sur un mur en bois Cet appareil ne do...

Страница 7: ...rr t Manuel On peut tout moment arr ter le fonctionnement automatique en revenant sur manuel ou sur arr t 6 Coupe circuit thermique Pour votre s curit le convecteur est pourvu d un coupe circuit therm...

Страница 8: ...VDE Vorschriften die Bestimmungen der rtlichen Versorgungsunternehmen oder unsere Montage und Gebrauchsanweisung nicht beachtet worden sind Durch etwa seitens des Endabnehmers oder Dritter unsachgem v...

Отзывы: