IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Important Safety Advice

DO NOT

 use the heater in the immediate 

surroundings of a bath, a shower or a swimming 

pool.

DO NOT

 place the heater directly below a fixed 

socket outlet.

DO NOT COVER

 or obstruct the air inlet and 

outlet openings in any way.

DO NOT

 operate the heater with the mains lead 

overhanging the front outlet grille.

The heater carries the warning symbol to 

indicate that it must not be covered.

WARNING:

 In order to avoid overheating do not 

cover the heater.

The instruction leaflet belongs to the appliance 

and must be kept in a safe place. If changing 

owners, the leaflet must be surrendered to the 

new owner.

IMPORTANT:

 If the mains lead of this appliance is 

damaged, it must be replaced by the manufacturer 

or its service agent or a similarly qualified person 

in order to avoid a hazard.

WARNING:

 In order to avoid a hazard due to 

inadvertent resetting of the thermal cut-out, 

this appliance must not be supplied through an 

external  switching  device,  such  as  a  timer,  or 

connected to a circuit that is regularly switched 

on and off by the utility.
This appliance can be used by children aged from 

8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of 

experience or knowledge if they have been given 

supervision or instruction concerning the use of 

the appliance in a safe way and understand the 

hazards involved. Children shall not play with the 

appliance. Cleaning and user maintenance shall 

not be made by children without supervision.
Children of less than 3 years should be kept away 

unless continuously supervised. Children aged 

from 3 years and less than 8 years shall only 

switch on/off the appliance provided that it has 

been placed or installed in its intended normal 

operating position and they have been given 

supervision or instruction concerning the use of 

the appliance in a safe way and understand the 

hazards involved. Children aged from 3 years and 

less than 8 years shall not plug in, regulate and 

clean the appliance or perform user maintenance.

CAUTION:

 Some parts of this product can 

become very hot and cause burns. Particular 

attention has to be given where children and 

vulnerable people are present.
Avoid  use  of  an  extension  cord  because  the 

extension cord may overheat and cause risk of 

fire.

Ensure the PFH30R remote control unit is earthed.

Always disconnect the supply before working on the product.

Always ensure combustible materials such as drapes or 

other furnishings are kept clear of the air inlet and air outlet.

This product should be mounted safely to a solid wall.

Ensure the supply cables are of adequate current carrying 

capacity and are protected by a suitable fuse.

General

Thank you for purchasing this high power wall mounted fan heater. 

Designed to provide heating for small commercial environments 

such as garages and workshops.
The heaters work by gradually raising the air temperature in a 

garage or workshop and should be positioned at head height 

approximately (1.8m - 2.3m - see 

Fig. 2

) where the controls can 

reached. 
The PFH30 and PFH30R heaters have an output of 3kW.
The angle the appliance is mounted at may be adjusted horizontally 

and vertically - see

 Fig. 1 

and 

Fig. 4

.

Electrical

The installation of this appliance should be carried out by a 

competent electrician and be in accordance with the current 

IEE wiring regulations. The supply cable is not supplied with the 

appliance.
Note: A suitable local isolating switch must be provided in the 

electrical supply circuit as close as possible to the heater with at 

least 3mm clearance on each pole. 

Wall Mounting

Remove the screw (see ‘z’ in 

Fig. 3C

)

 

to remove the cover bracket. 

Use the wall mounting bracket (see ‘x’ in 

Fig. 3A

) as a guide to 

mark off the hole positions on a suitable wall (a minimum height 

of 1.8 metres is required from the floor level to the bottom hole of 

the bracket - see 

Fig. 2

). Solid brick or concrete block walls must 

be drilled and plugged using the screws and wall plugs provided. 

Fix the wall mounting bracket to the wall and slide the heater down 

on to the bracket as shown in 

Fig. 3A

Note: Ensure there is enough clearance above the wall mounting 

bracket for the user to slide the heater onto the bracket. 
The heater is held in place to the wall mounting bracket with 2 

screws - see 

Fig. 3B

Once electrical connections have been completed - see ‘Electrical 

Installation’, re-attach the bracket cover (see ‘y’ in 

Fig. 3C

) by 

sliding into place and secure with the screw - see ‘z’ in 

Fig. 3C

.

Pivot and rotate the heater into the desired position and tighten 

the screw to secure - see ‘w’ in 

Fig. 4

.

Electrical Installation

Before undertaking electrical installation, ensure the electricity 

supply is disconnected from any relevant fixed wiring. With the 

bracket cover removed proceed to feed the supply cord through 

the cable entry at the bottom of the mounting bracket (drill knock-

out to suit).

Dimplex Compact Commercial Fan Heater

Models : PFH30 and PFH30R (Remote Control)