background image

Figure 3

C

E F

g

H

I

A - Setting/Temperature Display

B - Comfort Setting Icon

C - Economy Setting Icon 

D - Set Back Temperature Setting

E - Synchronized Icon

F - Lock Icon

G - Decrease Button

H - Increase Button

I - Menu Button

A

D

B

C. Economy setting

 

The Economy Setting can be used to change the Setpoint 

Temperature for a user determined period of time. By 

pressing the 

v

 the Economy Setting will be enabled - 

signified by the icon flashing. After the Set Back Temperature 

has been set, the icon will become solid after three seconds 

and the Set Back Temperature will be enabled.
To return back to the Comfort Setting press the 

v

 button. The 

 icon will disappear and the   icon will appear. 

D. set Back Temperature setting

 

The Set Back Temperature Setting is used during periods 

when the Economy setting feature is active. This temperature 

adjustment can be set by pressing the 

v

 followed by the 

 

or 

E. synchronized Icon

 

The PCH features COnnEX

TM

, a wireless technology that 

works with Dimplex single and multi-zone COnnEX

TM

 

controllers to provide simple whole home connectivity and 

comfort. COnnEX

TM

 controllers are available to control one 

or multiple Precision Comfort Heaters within a 50’ (15 m) 

radius. In order for the controller to have this function the 

PCH and the controller will need to be synchronized. To do 

this:

On the PCH heater press and hold the 

1. 

v

 button for 3 

seconds, both the 

 and 

 icons will begin to flash.

Press the 

2. 

 , 

 and then 

v

, on the PCH heater.

Within 10 seconds press any button once on the 

3. 

COnnEX

TM

 Controller.

!

 NOTE:

 There is a 3 second delay between pressing the 

last button on the controller and the PCH heater.

!

 NOTE:

 To desynchronize a PCH heater from the 

synchronized COnnEX

TM

 Controller; on either the PCH 

heater or the controller:

Press and hold the

1. 

 v

 for 3 seconds.

Press the 

2. 

v

 and then 

.

Nothing will need to be done to the other component.

Dimplex single and multi-zone COnnEX

TM

 controllers are 

3

sold separately and are available for purchase from your 

authorized Dimplex dealer.
To find your local Dimplex dealer, visit www.dimplex.com.

F. lock Icon

 

The PCH has a Button Lock feature to prevent settings from 

accidentally being changed.

Press and hold the 

1. 

v

 for 3 seconds. Both the 

 and   

Icons will begin to flash.

To Enable: 

2. 

Within 5 seconds press 

, then 

, then 

then 

. The   icon will appear

To Disable: 

Within 5 seconds press

 

, then 

, then

 

then 

. The   icon will disappear. 

!

 NOTE: 

The PCH can be locked in either the Comfort or 

Economy Setting. Ensure that the desired icons are present 

when locking is complete.

Boost Function

The PCH is also equipped with a “Boost Function” 

which allows the user to run the unit at full heat, for a 

predetermined amount of time, to quickly heat up a cold 

room/space. The Boost can be set for a maximum of 20 

minutes, in 5 minute increments.
To enable Boost:

Press and hold 

1. 

 for 5 seconds. The area where the 

temperature normally displays will begin to toggle 

between the display of “HI” and “20”.

!

 NOTE: 

The “20” indicates the time (in minutes) remaining 

in Boost function. The timer is updated as the time counts 

down 19, 18, 17, etc.

The length of time that Boost is enabled for can be 

2. 

adjusted by pressing the 

 or 

 buttons. Every time the 

 or 

– 

button is pressed the timer will be adjusted by 5 

minutes and will cycle back to 20 minutes.
When the timer times out the heater will return to the 

3. 

programmed settings.

!

 NOTE: 

At any time you can hold down the

 

 

button for 5 

seconds and exit the Boost function.