background image

2

www.dimplex.com

2 x 3 Framing

1.  Unpack the heater from the carton.
2.  Determine the correct mounting height for the heater. 

The bottom of the heater should be mounted a minimum 

of 8” (20.3 cm) from the floor. The recess box is designed 

so that it can be mounted between two studs within the 

wall.

3.  The recess box requires an opening in the wall 13.5” 

(34.5 cm) high by 8 3/8” (21.5 cm) wide (see Figure 2).  

The depth of the opening must be 2 7/8” (7.3 cm).  This 

is measured from the finished wall surface. 

4.  Bend the four tabs out to secure the recess box to the 

drywall.

!

 NOTE: 

The sides of the recess box are marked with 

guidelines to allow for ½” and ⅝” drywall thickness. When 

installing the recess box before installing drywall, use the 

depth guidelines to mount the box at the appropriate depth 

for drywall  thickness, and proper grille installation.
5.  Remove appropriate electrical knockout and secure sup-

ply wire using an approved strain relief connector, leav-

ing 6” (15.2 cm) of wire leads in the recess box. (Figure 

2)

!

 NOTE: 

It is only necessary to remove the knockout that 

will feed the power supply wiring, keeping in mind the heater 

mounting location and supply wire location on the wall.
6.  Slide the spacer on to the recess box so that the front 

flange of the spacer is located behind the front flange of 

the recess box.

!

 NOTE: 

The bottom ends of the spacer may need to be 

separated slightly to ensure it slides over the recess box 

more smoothly and the ends may need to be bent in slightly 

once installed to ensure proper fit.
7.  Proceed to the wiring instructions.

Supply Wiring and Heater Installation

  

WARNING: 

Wiring procedures and connections should 

be in accordance with the National Electric Code (NEC & 

CEC) and local codes.

Figure 3

Securing Tabs

Retaining Screw

Washable Filter

M

L1

L2

R

G

Cutout

Over 

Temperature 

Light

Control 

Board

Display 

Board

Motor

Heater

Temperature 

Sensor

Wiring

8 3/8”

(21.5 cm)

13 1/2”

(34.5 cm)

Figure 2

Electrical 

Knockouts

Front Mounting 

Holes

Side 

Mounting 

Holes

Top Mounting 

Holes

For securing Front Panel

Do not use for mounting!

Mounting 

Tabs

1.  Insert approximately 6” (15.2 cm) of supply wire into 

recess box through the desired knockout. Wire should be 

rated for a minimum of 75°C (167°F)

2.  Connect power supply to terminals provided marked L1 

and L2. Ground wire should be secured to green wire 

provided inside of the heater assembly. 

  

WARNING: 

All units are factory prewired for operation 

with the built-in thermostat. THIS HEATER IS NOT TO BE 

USED WITH A REGULAR WALL THERMOSTAT.

3.  Do a final and complete check of all wiring.
4.  Attach heater by hanging heater on upper tabs then se-

curing at the bottom using the supplied screw. (Figure 3)

5.  Insert the air filter through the bottom slot, until it clicks 

into place.

  

WARNING: 

TO PREVENT THE RISK OF FIRE OR IN-

JURY, DO NOT OPERATE THE HEATER UNLESS IT IS 

FULLY ASSEMBLED.

!

 NOTE: 

Prior to energizing remove all construction dirt 

(plaster, sawdust, etc.) from interior and exterior of heater.

Отзывы: