Digital Timer Operation 

(see

 Fig. 6

)

IMPORTANT:

 Remember to observe all safety warnings 

when operating the heater on auto setting, either attended 

or unattended.
The timer allows you to select ‘

AUTO

’ or ‘

MAN ON

’ by 

pressing the ‘MODE’ button until the required MODE 

appears at the bottom of the timer display.

AUTO

’ MODE allows the heater to switch ON and OFF 

according to a set 24 Hour program period (see ‘Setting 

Programs’ section below).

MAN ON

’ MODE allows power to the heater uninterrupted 

by the program settings. 

Key Lock:

If ‘

ENTER

’ and ‘

MODE

’ are pressed within 1 second, the 

keys will be locked. The user will know the keys are locked 

as the lock symbol ‘ ’ will be displayed on the top left hand 

corner of the screen. To unlock the keypad, press ‘

ENTER

’ 

and then ‘

MODE

’ within 1 second.

Initial Operation 

For initial use, plug the heater into a regular household 

power point and turn the power on.  The timer is now ready 

to be set up for use.

Setting Current Time

1. Hold the ‘

PROGRAM

’ button until the clock symbol   

appears on the screen and the hour digit flashes.  The user 

can now set the clock. 
2. To adjust the hour use the ‘

-

‘ & ‘

+

’ buttons. Confirm the 

hour digit by pressing ‘

ENTER

’. 

3. Once ‘

ENTER

’ has been pressed the minutes will flash.  

To adjust the minutes use the ‘-‘ & ‘+’ buttons. Confirm the 

minute digit by pressing ‘

ENTER

’.

4. The timer now returns to the default display.
5. To reset incorrect time, repeat previous steps.
Once the correct time is set, a total of four ON/OFF time 

programs can be set for operation. 

Setting Programmes

Press the ‘

PROGRAM

’ key to set the programs. 

You are now setting the programs starting with P1 ‘ON’.

SETTING P1 ON TIME:

1. To set the hour use the ‘

-

‘ & ‘

+

’ buttons. Confirm the hour 

digit by pressing ‘

ENTER

’. 

2. To set the minutes use the ‘

-

‘ & ‘

+

’ buttons. Confirm the 

minute digit by pressing ‘

ENTER

’.

Note: The minutes can only be set in 10 minute blocks in 

programme ‘

MODE

’. 

SETTING P1 OFF TIME:

3. To set the hour use the ‘

-

‘ & ‘

+

’ buttons. Confirm the hour 

digit by pressing ‘

ENTER

’. 

4. To set the minutes use the ‘

-

‘ & ‘

+

’  buttons. Confirm the 

minute digit by pressing ‘

ENTER

’.

Repeat steps 1 to 4 to programme P2, P3 & P4. After 

programming P4 ‘OFF’ you automatically exit to the default 

display.
At any time while programming the timer you can press the 

PROGRAM

’ button to exit to the default display.

Note: If the ‘ON’ time is the same as the ‘OFF’ time the 

appliance will ignore the program. 

The Advance Function

When in ‘

AUTO

’ MODE, if the ‘

+

’ button is pressed for 

longer than 2 seconds the programme will ADVANCE to the 

next setting programmed and will only revert back to the 

program when the subsequent programme time is reached. 

When the ‘

ADVANCE

’ function is running the ‘

ADVANCE

’ 

segment will be displayed on the LCD screen. If the ‘

-

‘ button 

is pressed when the ‘

ADVANCE

’ programme is running the 

ADVANCE

’ feature will be automatically cancelled and the 

programme will run as normal. 

Note - Timer Memory Back Up Batteries 

- Once the heater 

has been left plugged in with the socket switched on for at 

least 72 hours the timer’s memory back up batteries will 

be fully charged.
Once the timer batteries are fully charged, if there is a power 

cut or if the heater is disconnected from the mains for less 

than six months, then the timer will continue to keep time 

& the settings in the memory will remain intact.
If however the timer back up batteries have not been 

charged fully, or if the heater is deprived of power for 

longer than six months, then the time and the programme 

settings are likely to be lost and you may therefore need to 

reset the time and the programme before using the AUTO 

MODE again.

Содержание OFRC15

Страница 1: ...ll portable heating appliances This product is only suitable for well insulated spaces or occasional use The product complies with the European Safety Standards EN60335 2 30 and the European Standard...

Страница 2: ...N A B C 2 1 ALL TI MODELS ONLY ALL MODELS Thermostat Neon On Off Heat Switches 24 Hr Timer 3 4 5 6 On Off see Table 1 Cable wrap ALL MODELS 5 Fin 7 9 11 Fin OFRC10 OFRC10TI OFRC15 OFRC15TI OFRC20 OFRC...

Страница 3: ...throom DO NOT place the heater directly below a fixed socket outlet WARNING In order to avoid overheating do not cover the heater We recommend that you open a window to ventilate the room when using t...

Страница 4: ...astors are designed to be a tight fit on the axles but will rotate in use The castors can only be fitted between the outer fins as shown in Fig 2 Turn the heater upside down on a carpet or other soft...

Страница 5: ...stat just clicks off The heater will now automatically operate at this temperature With the thermostat set to and the heat selection switch set to the required heat output the appliance switches on au...

Страница 6: ...our digit by pressing ENTER 2 To set the minutes use the buttons Confirm the minute digit by pressing ENTER Note The minutes can only be set in 10 minute blocks in programme MODE SETTING P1 OFF TIME 3...

Страница 7: ...nstalled and operated in accordance with the manufacturer s instructions and used solely for domestic purposes c The defect fault was not as a result of accident misuse unauthorised modification or in...

Страница 8: ...ear Guarantee Period afresh from the date of delivery of the replacement Dimplex product to you The Dimplex Guarantee does not entitle you to recovery of any indirect or consequential loss or damage i...

Отзывы: