Product Locks

Product Locks are methods of locking the heater’s controller to restrict access to functions. This can be activated 

and confi gured via the Advanced Settings Menu.

When  Product  Lock  is  activated,  the  heater  continues  to  run  in  whichever  mode  is  currently  active  and  any/all 

wireless communications remain active if enabled.

Child Lock

This locking method does not utilise a PIN code and is toggled on/off  on the heater’s controller by pressing and 

holding the 

Back

 and 

Enter

 buttons for three seconds. It is a full Product lock with no exception rules.

PIN Lock

In 

PIN Lock

, all UI buttons other than the 

Menu

 button are disabled unless 

Advance

 has been enabled during UI 

Lock (see section ‘Product Lock Settings’ on page 20).

In the Main Menu all buttons are active. Two items can be selected: 

Boost

 – Activates Boost Mode. This function can be restricted, see below.

Unlock

 -  Selecting ‘Unlock’ prompts the User to complete the unlock action for the currently active.

Manual

21

°

C

Heating ON

Menu

Boost

Unlock

PIN Lock

134--

Enter 4 Digit 

PIN

PIN Unlocked

18

Содержание MFP 100E

Страница 1: ...Monterey MFPE Models MFP050E MFP075E MFP100E MFP150E MFP200E These instructions should be read carefully and retained for future use Note also the information presented on the appliance INSTRUCTION MA...

Страница 2: ...ire risk NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater WARNING THE SURFACES ON THIS HEATER CAN BE HOT The heater ca...

Страница 3: ...rs combined with the convection effect of electric heaters can cause significant soot deposits to build up on the surface directly above and to the sides of the heater This is not a fault of the heate...

Страница 4: ...iring of the premises through a suitable connection box positioned adjacent to the heater A means for disconnection must be incorporated in the fixed wiring of the premises in accordance with the curr...

Страница 5: ...g and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less than 8 yea...

Страница 6: ...inal heat output Pnom 0 5kW 0 75kW 1 kW 1 5kW 2 0kW Height mm 536 536 536 536 536 Width mm 503 503 671 741 911 Depth mm 104 104 104 104 104 Minimum heat output indicative Pmin N A N A N A N A N A Maxi...

Страница 7: ...vered upward facing grille Advanced controls with capacitive sense technology for total exibility of heating Colour Finish Metal Chassis Air Outlet Grille Control Moulding Traffic White RAL 9016 Eleme...

Страница 8: ...ame as that stated on the heater MODEL A B C D E MFP050E 390mm 150mm 503mm 536mm 104mm MFP075E 390mm 150mm 503mm 536mm 104mm MFP100E 560mm 150mm 671mm 536mm 104mm MFP150E 630mm 150mm 741mm 536mm 104mm...

Страница 9: ...es Ensure only screw fittings suitable for the particular wall type are used 3 Present the heater to the wall bracket and engage bottom slots in the back with bracket hooks 4 Press the top of the heat...

Страница 10: ...ar after a short period of use It is however advisable to keep the room well ventilated The controls are located on top of the heater This consists of a display screen and six touch sensitive buttons...

Страница 11: ...currently active mode of operation is displayed at the top of the screen e g Out All Day timer When the heater is trying to achieve or maintain a room temperature Heating On will be displayed otherwi...

Страница 12: ...eriod when that period is active This will temporarily adjust the Target Temperature for just that instance and will not permanently modify the settings for the timer in use NOTE If Adaptive Start is...

Страница 13: ...ew This option displays the timer s con guration This is handy to quickly check the timer without being able to change any values ADVANCE MENU BACK ENTER Manual 21 C Heating ON Period 1 Period 2 Perio...

Страница 14: ...ave time when modifying a Timer Mode the Advance button can be used to copy and paste settings Individual heating periods from one day or every heating period from a day can be copied to another day C...

Страница 15: ...s are set separately on the heater making the feature useful for popping out to the shops or going away on holiday The date set is the return date therefore Away mode will end at 23 59 of the day befo...

Страница 16: ...t 7 C Not User De nable ADVANCE MENU BACK ENTER Modes Timer Mode Manual Eco Mode Frost Protect ADVANCE MENU BACK ENTER Manual 21 C Heating ON These functions modify the normal behaviour of the heater...

Страница 17: ...The Advance Function The Advance button is only used when a Timer Mode is active and allows the timer schedule to be changed temporarily This button allows a Heating On period to begin or end early T...

Страница 18: ...ter s controller by pressing and holding the Back and Enter buttons for three seconds It is a full Product lock with no exception rules PIN Lock In PIN Lock all UI buttons other than the Menu button a...

Страница 19: ...y it would if the UI was not locked only if the Heater is Locked into a Timer Mode If Advance is enabled during UI lock the Advance button will function as normal while the Heater is set to a Timer Mo...

Страница 20: ...s as well as enable disable modi cation of the Boost Temperature and Boost Duration See below Boost Lock Three settings can be modi ed within this Menu Enable Disable The Boost Menu Item can be Enable...

Страница 21: ...the Time Date and Daylight Savings Time settings to be modi ed Sound Audio feedback when the user presses a button can be enabled or disabled here Comms Communications This allows Wireless Connectivi...

Страница 22: ...e by the start of the Heating On period For example with Adaptive Start off the Heating On time is the time that the Heater will begin to try and achieve the Target Temperature With Adaptive Start On...

Страница 23: ...a Excessive temperatures FAULT_CODE_EXCESSIVEROOMTEMP_FAILURE 30 FAULT_CODE_LCD_OVERHEAT 32 FAULT_CODE_EXCESSIVEACCTEMP_FAILURE n a FAULT_CODE_FAN_FAILURE n a Internal Failures FAULT_CODE_SERIAL_COMM...

Страница 24: ...and locate the battery module 2 Slide the catch and pull module from the controls 3 Remove the coin cell battery and replace 4 Slide module back in place ensuring clip is engaged 4 Battery positive si...

Страница 25: ...the product on and make sure that the RF comms are enabled Comms settings will be located in the settings menu see page 21 During the initial operation some odour may be noticed due to the newness of...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...t prior permission in writing of Glen Dimplex Customer Helpline 0344 879 3588 www dimplex co uk Glen Dimplex Heating Ventilation Millbrook House Grange Drive Hedge End Southampton SO30 2DF This produc...

Отзывы: