www.dimplex.de 452162.66.04 · FD 9309
EN-19
Englis
h
LAW 9IMR - LAW 14ITR
6
Electrical connection
6.1
Supply voltage / fuse protection
Compressor
1~/N/PE 230 V (50 Hz) / C25 A
Heating cartridge
1~/N/PE 230 V (50 Hz) / C35 A
Comp heating cartridge
3~/N/PE 400 V (50 Hz) / C32 A
3~/N/PE 400 V (50 Hz) / C32 A
RCD-Type
B
B
6.2
Control voltage / fuse protection
1~/N/PE 230 V (50 Hz) / C13 A
1~/N/PE 230 V (50 Hz) / C13 A
6.3
Degree of protection according to EN 60 529 indoors/outdoors
IP 20 / IP X4
IP 20 / IP X4
6.4
Starting current limiter
Inverter
Inverter
6.5
Rotary field monitoring
Yes
Yes
6.6
Starting current
A
1,2
1,3
6.7
Nominal power consumption at A7/ W35 /
max. consumption
5
10
kW
2,11 / 10,91
6
3,39 / 13,78
6
6.8
Nominal current at A7/W35 / cos
A / --
9,27 / 0,99
4,94 / 0,99
6.9
Nominal power consumption at A2/ W35
10
1,91
3,50
6.10 Power consumption of compressor protection
(per compressor)
W
--
--
6.11 Power consumption of fan
W
124
248
7
Complies with the European safety regulations
7
7
8
Additional model features
8.1
Type of defrosting
Reverse circulation
Reverse circulation
8.2
Condensate tray frost protection /
water in device is protected from freezing
8
No / Yes
Yes/ Yes
8.3
Max. operating overpressure (heat source/heat sink)
bar
3,0
3,0
9
Heat output / coefficient of performance (COP)
9.1
Heat output / coefficient of performance (COP)
5
EN 14511
EN 14511
at A-7 / W35
kW / ---
9
6,7 / 2,8
13,9 / 2,9
kW / ---
10
6,7 / 2,8
13,9 / 2,9
at A2 / W35
kW / ---
9
5,3 / 3,6
10,5 / 3,6
kW / ---
10
6,2 / 3,2
11,0 / 3,2
at A7 / W35
kW / ---
9
5,6 / 4,8
10,6 / 4,1
kW / ---
10
9,0 / 4,3
14,7 / 4,3
at A7 / W45
kW / ---
9
5,4 / 3,4
9,8 / 3,7
kW / ---
10
8,3 / 3,3
13,9 / 3,3
at A10 / W35
kW / ---
9
6,0 / 5,1
11,3 / 4,5
kW / ---
10
9,6 / 4,5
15,7 / 4,3
9.2
Cooling capacity / coefficient of performance (COP)
at A27 / W7
kW / ---
10
6,5 / 3,3
12,9 / 3,0
at A27 / W18
kW / ---
10
8,7 / 4,2
17,1 / 3,7
at A35 / W7
kW / ---
10
6,2 / 2,6
12,3 / 2,5
at A35 / W18
kW / ---
10
9,0 / 3,4
15,5 / 3,3
1. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3 dB (A).
2. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
3. Please note that additional space is required for pipe connections, operation and maintenance.
4. Delivery state 6 kW
5. This information shows the size and performance of the system in accordance with EN 14511. For economical and energy-related considerations, the bivalence point and control
must be taken into account. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning and operation can be found in the relevant sections
of the installation and operation instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and heating water flow temperature
35 °C.
6. Max. intake incl. pipe heating and immersion heater (state of supply)
7. See CE declaration of conformity
8. The heat circulating pump and the heat pump controller must always be ready for operation.
9. COP-optimised operation
10.Maximum heating/cooling output
Содержание LAW 14ITR
Страница 2: ......
Страница 22: ...DE 20 452162 66 04 FD 9309 www dimplex de Deutsch LAW 9IMR LAW 14ITR ...
Страница 42: ...EN 20 452162 66 04 FD 9309 www dimplex de English LAW 9IMR LAW 14ITR ...
Страница 62: ...FR 20 452162 66 04 FD 9309 www dimplex de Français LAW 9IMR LAW 14ITR ...
Страница 72: ...A XII 452162 66 04 FD 9309 www dimplex de Anhang Appendix Annexes LAW 9IMR LAW 14ITR 3 3 Last Load Puissance ...
Страница 83: ...www dimplex de 452162 66 04 FD 9309 A XXIII Anhang Appendix Annexes LAW 9IMR LAW 14ITR ...