www.dimplex.de
E-9
E
n
g
li
s
h
12
12 Equipment Data
Equipment Data for Air-to-Water Heat Pumps for Heating
1
Type and Commercial Description
LAK 10M
2
Model
2.1
Type
Compakt
2.2
Enclosure type acc. to EN 60 529
IP 24
2.3
Installation site
Outdoors
3
Performance Data
3.1
Operating temperature limits:
Heating water supply / return
1
°C / °C
1. For outside air between -20° C to 0° C, flow temperature increasing from 49° C to 58° C.
Up to 58 +/- 2 / above 18
Air (heat source)
°C
-20 to +35
3.2
Temperature spread of heating water according
at A7/W35
K
10.9
5.0
3.3
Heating capacity / coeff. of perform at A2 / W35
2
kW / ---
2. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For economic and energetic considerations, additional factors such as defrosting
behaviour, bivalence point and control need to be taken into account. Abbreviations have the following meaning: e.g. A7 / W35: outside temperature 7 °C and heating water supply
temperature 35 °C.
8.1 / 3.4
8.0 / 3.2
at A7 / W35
2
kW / ---
10.2 / 4.1
9.7 / 3.8
at A7 / W45
2
kW / ---
8.7 / 3.1
at A10 / W35
2
kW / ---
11.5 / 4.5
10.9 / 4.2
at A-7 / W35
2
kW / ---
5.6 / 2.5
3.4
Sound power level
dB(A)
72
3.5
Sound pressure level at 10 m distance (discharge side)
dB(A)
46
3.6
Heating water flow with an internal pressure differential
m³/h / Pa
0.8
3
/ 1100
3. Recommended heating water flow rate
1.65
4
/ 4500
4. minimum heating water flow rate
3.7
Free pressure, heating circulating pump (max. stage)
Pa
65000
60000
3.8
Refrigerant; total charge weight
type / kg
R404a / 2,3
3.9
Output of electric heating element adjustable
(heat exchanger 2)
kW
2.4 max. 6
4
Dimensions, Connections and Weight
4.1
Equipment dimensions
H x B x L mm
880 x 1285 x 695
4.2
Equipment connections for heating
inch
G 1'' external
4.3
Weight of transport unit(s) incl. packaging
kg
185
5
Electrical Connection
5.1
Nominal voltage; fusing
V / A
230 / 25
5.2
Heat element fuse
5
A
5. To establish an electrical connection for the heating element, a special mains cable with separate fuse is required.
30
5.3
Starting current with soft starter
A
32
5.4
Nominal power consumption
2
A7 / W35
kW
2.5
2.6
5.5
Nominal current A7 / W35 / cos
M
A / ---
13.6 / 0.8
14.1 / 0.8
6
Complies with European Safety Regulations
6
6. See CE Declaration of Conformity
7
SOther Design Characteristics
7.1
Defrosting
automatic
Defrost type
cycle reversal
Defrost pan available
yes (heated)
7.2
Heating water inside unit protected against freezing
yes
7
7. The heating circulating pump and the controller of the heat pump must be on standby at all times.
7.3
Performance settings
1
7.4
Controller internal/external
internal