OPTION 6 – SPACE HEATING PRIORITY
HEAT
█
,
PrY
Press
SELECT
Press
▲▼
Display
NO
Press
S E T
to Store
Option 7 Press
▼
OPTION 5 – SPACE HEATING PRIORITY
HEAT
█
,
PrY
Press
SELECT
Press
▲▼
Display
YES
Press
S E T
to Store
Option 6 Press
▼
OPTION 4 – HOT WATER PREPARATION –
YES
TANK
█
,
con
Press
SELECT
Press
▲▼
Display
YES
Press
S E T
to Store
Option 5 Press
▼
Pre
Configuration
– Hydraulic
Design
Is the heat pump preparing hot water via a suitable hot
water cylinder.
Either NO or YES as Indicated in OPTION 3.
Y E S
- the heat pump is preparing hot water and is
connected to a suitable heat pump hot water cylinder.
Is space heating to be given priority.
Either NO or YES as Indicated in OPTION 6.
Y E S
- the heat pump gives priority to space heating.
Hot water will only be prepared once the space heating
demand is satisfied.
Is space heating to be given priority.
Either NO or YES as Indicated in OPTION 5.
N O
- the heat pump gives priority to hot water preparation
based upon the following settings, OPTION 7 & OPTION 8
Below.