E-8
English
11
11 Device Information
1
Type and order code
LA 40AS
2
Design
2.1
Model
Universal
2.2
Degree of protection according to EN 60 529
IP 24
2.3
Installation location
Outdoors
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
°C / °C
up to 58 ± 2 / above 18
Air (heat source)
°C
-25 to +35
3.2
Temperature spread
of heating water
at A7 / W35
K
7,8
5,0
3.3
Heat output / COP
at A-7 / W35
1
kW / ---
2
1. This data indicates the size and capacity of the system according to EN 255 or EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters,
in particular the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values have the following meaning, e.g. A7 / W35:
7 °C external air temperature and 35 °C heating water flow temperature.
2. Operation with 2 compressors
24,3 / 3,1
23,8 / 3,0
kW / ---
3
3. Operation with 1 compressors
13,8 / 3,2
13,5 / 3,1
at A2 / W35
1
kW / ---
2
30,4 / 3,9
30,0 / 3,8
kW / ---
3
17,1 / 4,0
16,8 / 3,9
at A7 / W35
1
kW / ---
2
36,3 / 4,5
35,7 / 4,4
kW / ---
3
20,2 / 4,7
20,0 / 4,6
at A7 / W55
1
kW / ---
2
33,9 / 2,8
33,1 / 2,7
kW / ---
3
18,0 / 2,8
17,6 / 2,7
at A10 / W35
1
kW / ---
2
38,5 / 4,8
38,1 / 4,7
kW / ---
3
22,0 / 5,0
21,7 / 4,9
3.4
Sound power level
dB(A)
70
3.5
Sound pressure level at a distance of 10 m
(air outlet side)
dB(A)
43
3.6
Heating water flow rate / internal pressure differential of m³/h / Pa
4,0
4
/ 1700
4. minimum heating water flow rate
6,2
5
/ 3900
5. recommended heating water flow rate
3.7
Air flow
m³/h
11000
3.8
Refrigerant; total filling weight
type / kg
R404A / 11.8
3.9
Lubricant; total filling quantity
type / litre
Polyolester (POE) / 4.1
4
Dimensions, connections and weight
4.1
Device dimensions without connections
H x W x L mm
2100 x 1735 x 890 (750)
4.2
Device connections to heating system
Inch
Thread 1 1/2'' external
4.3
Weight of the transportable unit(s) incl. packing
kg
585
5
Electrical Connection
5.1
Nominal voltage; fuse protection
V / A
400 / 25
5.2
Starting current with soft starter
A
30
5.3
Nominal power consumption A2 W35
1
2
kW
7,79
7,89
5.4
Nominal current A2 W35 / cos
ϕ
2
A / ---
14,05 / 0,8
14,24 / 0,8
5.5
max. power consumption of compressor protection
(per compressor)
W
70; thermostatically controlled
6
Complies with the European safety regulations
6
6. see CE declaration of conformity
7
Additional model features
7.1
Defrosting
Automatic
Type of defrosting
Reverse circulation
Defrosting tray included
Yes (heated)
7.2
Water in device protected against icing
7
7. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes
7.3
Performance levels
2
7.4
Regulator internal/external
External
Содержание LA 40AS
Страница 2: ......
Страница 30: ...F 10 Français 11 ...
Страница 35: ...www dimplex de A V Anhang Appendix Annexes 3 2 3 2 Last Load Charge LA 40AS ...
Страница 36: ...A VI Anhang Appendix Annexes 3 3 3 3 Anschlussplan Circuit Diagram Schéma électrique LA 40AS ...
Страница 43: ...www dimplex de A XIII Anhang Appendix Annexes 6 ...