4
The Heater is equipped with a thermostat (3) which you can
use to set the room temperature you want. The
∗
setting
of the
themostat is for frost protection. Here the thermostat keeps the
room temperature at around 7°C. A room temperature of about
21 °C corresponds to a ‘6’ setting on the thermostat knob.
4a. Restricting the Temperature Range
With the aid of the two pins (1) on the back of the unit you
can set the range of the thermostat wheel. One pin
determines the upper value and the other pin the lower
value. Move the pins back and forth to loosen them.
4b. Locking the Controls
You can lock the controls flap to prevent unauthorized
tampering with the controls.
Undo the screw (2) at the back of the control panel and
screw it in at the position shown in the diagram above.
5. Overheating Cutout
For your protection the heater is equipped with an
overheating cutout. If the outgoing flow of air is obstructed
(for example, the air grille is covered or is closed), the
heater will cut out automatically.
Do not put the heater back into operation until you have
corrected what caused the overheating cutout to trip. You
should also switch off the power supply to the unit for a few
minutes (mode switch to OFF).
Once the unit has cooled down enough you can switch it
back on.
For you to enjoy the full power of the heater the air intakes
and outlets must be kept free of dust. Clean the heat with
your vacuum cleaner before the cold season of the year.
6. Faults
If no heat is coming out of the convector make sure that the
mode switch is set correctly (see Section 4) and that the
thermostate is set to the temperature you want. Check that
the circuit-breaker has not tripped or that the fuse has not
blown. In the event of malfunctions in your heater, please
contact your local electrician or the nearest customer
service point for Dimplex appliances. The E number and the
FD code are required before servicing can be carried out.
You will find them on the rating plate.
7. Cleaning
Before attempting any cleaning operation,
switch off the heater and wait until it has
fully cooled down. The heater can be
swung away from the wall to allow access
for cleaning: Undo the fastening and pull
the top of the heater forwards. Use a soft
damp cloth to wipe off the outside
surfaces of the heater. Do not use abrasives or furniture
polishes for cleaning as these can damage the surfaces of
the heater.
8. Technical Data, Dimensions, Weights
Supply voltage
1/N/PE~ 230V, 50Hz
Thermostat 7-29°C
Protection class l
With protective earth terminal
Degree of protection IP 21
Dripproof
Rating
Model
Weight
Dimensions in mm
W
kg
A
B
500 KSE
050
3,4
300
430
750 KSE
075
3,6
340
430
1000
KSE
100
4,2
420
430
1250
KSE
125
4,7
500
430
1500
KSE
150
5,5
580
430
1750
KSE
175
6,0
660
430
2000
KSE
200
6,6
740
430
500 KLE
050
3,7
580
220
750 KLE
075
4,7
820
220
1250
KLE
125
6,9
1060
220
1500
KLE
150
7,2
1300
220
9. Warranty
Authorised dealers can provide information on the terms
and conditions of warranty. The warranty is not valid without
a sales receipt marked with the date of purchase.
Disposal Notice
The product should not be disposed of with your
other household waste.
1
2
Glen Dimplex Deutschland GmbH
T49 (0) 9221 / 709-564
Subject to change
Am Goldenen Feld 18
T49 (0) 9221 / 709-589
www.dimplex.de
D-95326 Kulmbach
E-Mail: [email protected]
Germany
A
PE
N
Control wire
black
L1
105
83
B