General

The IRXE range of infra-red wall heaters are a safe, practical 

source of heat in bathrooms, kitchens, work areas - anywhere 

where fast localised heating is required. The IRXE uses quartz 

elements which emit a warm glow of medium wave infra-red. 

The IP24 rating means the appliance is suitably rated to be 

permanently installed either internally or externally.

The installation of this appliance should be carried out by a 

competent electrician and be in accordance with the current 

IEE wiring regulations and any local or insurance regulations.
The IRXE is designed for use on a 230-240V AC single phase 

supply.  A double pole isolating switch with a minimum separation 

of 3mm in each pole must be fitted to facilitate isolation. This 

switch must either be positioned inside a building or have an IP 

rating against water ingress suitable for external installation. The 

appliance must be supplied through a residual current device 

(RCD) having a rated residual operating current not exceeding 

30mA. The appliance must be connected to a socket-outlet 

having an earthing contact (for Class I appliances).

Prior to installation remove the polystyrene inserts which secure 

the elements during transportation.                           

a.    Remove  the  two  front  grill  screws.                                                                        
b.    Remove  the  front  grill  in  the  direction  of  the  arrow.                                                                                                                
c.  Remove element protection polystyrene.    

Replace front grill and reverse procedure.

The heater must be permanently fixed to the wall using the 

wall mounting bracket and screws supplied. The heater must 

be mounted Horizontally as shown observing the minimum 

clearances stated in 

Fig. 2.

The minimum mounting height for the heater is 1.8 meters which 

requires that the the mounting holes for the wall bracket be 

drilled at a height of 1.9 meters.

The desired heating level can be set by pulling the pull cord 

switch once or repeatedly. The set heating level can be read in the 

display window. In position “0” the heating device is switched off. 

1. Remove the two screws which hold the front grill onto the 

heater. 

2. Remove the front grill in the direction of the arrow.
3. Remove the two element securing clips to release the element.
4.  Disconnect  the  element  wires  from  each  side  of  the  element.            
5. Reverse procedure with new element.

WARNING: 

BEFORE UNDERTAKING THIS TASK, ENSURE 

THE HEATER IS DISCONNECTED FROM THE ELECTRICITY 

SUPPLY AND LEFT TO COOL FOR A MINIMUM OF 30 

MINUTES

Since the appliance contains no moving parts little maintenance 

is required beyond cleaning and element replacement. It is 

however essential that the heater is not operated with an 

accumulation of dust or dirt on the element, as this can cause a 

build up of heat and eventual damage. For this reason the heater 

must be inspected regularly, depending upon conditions and at 

least at yearly intervals. Allow adequate time for the element and 

body casing to cool before attempting to work on the heater - a 

minimum time of 30 minutes is recommended. 
If the bulb is accidentally touched by bare fingers remove the 

fingerprint with a soft cloth moistened with methylated spirits.

WARNING: 

BEFORE UNDERTAKING CLEANING OR 

MAINTENANCE WORK ON THE APPLIANCE, DISCONNECT 

THE ELECTRICITY SUPPLY

Model

Display 0

Display 1 Display 1 Display 2

IRX60/120E

Off

600W

600W

1200W

Power output in switch position: 

W = output power in Watts

a. Remove the screw (a) to release the plastic control molding. 

This will allow the unit to tilt forward and allow access to the 

securing holes on the back of the unit  - see 

Fig. 3.

b. Place heater horizontally against the wall, mark and drill holes 

to suit and insert the two wall fixings supplied - see 

Fig. 3

c. Place the two plastic inserts into the holes provided on the 

control housing and tighten screws to secure heater - see 

Fig. 3

     

Replace control molding and fix heater to required angle.
The bracket allows the heater to be inclined at the required 

angle. The siting of the heater(s) should be such as to allow an 

even and uninterrupted distribution of radiation to the area(s) 

to be heated. Heaters are most effective when the beam angle is 

inclined down at an angle of between 30º to 45º to the vertical.  

When deciding upon the best location, consideration must be 

given to the following requirements:

a.

 Comfort and safety could be compromised unless the heater 

is mounted at or above 1.8m from ground level.

b. The minimum clearance distances must be maintained as 

shown in Fig. 2.

Technical Details

Electrical Connection

Remove Packaging (See Fig. 1)

Installation - Wall Mounting

Operation

Element Replacement (see Fig.4) 

Cleaning & User Maintenance

Model Identifier(s):

IRX60/120E

Nominal voltage

230-240V~

Degree of Protection

IP24

Dimensions (W x H x D)

768 x 100 x 92

Weight

1.6kg

Heat Output

Nominal heat output

Pnom

1.2kW

Minimum heat output 

(indicative)

Pmin

0.6kW

Maximum continuous 

heat output

Pmax, C

1.2kW

Intrinsic Consumption

At nominal heat output

elmax

0.00

At minimum heat output

elmin

0.00

In standby mode

elSB

<0.0005

Control for heat output

Two manual stages, no room temperature control