The domestic hot water heat pump is a ready-for-use heating de-
vice whose main components are a domestic hot water cylinder,
the components of the refrigerant, air and water circuits and the
control, regulation and monitoring devices required for automatic
operation.
The domestic hot water heat pump is supplied with electrical en-
ergy and uses the heat stored in the intake air for domestic hot
water preparation. The domestic hot water heat pump with inter-
nal heat exchanger can be connected to additional heat genera-
tors such as boilers and solar energy systems. A vertical clad-
ding tube (inner

 

12 mm) houses an external temperature

sensor. The devices are equipped as standard with an electric
heating element (1.5 kW).
The temperature of the intake air (the heat source) provides the
reference value for the energy consumption and the domestic hot
water preparation heating-up time.
Falling exhaust air temperatures reduce the heat pump output
and increase the heating-up time. In order for the heat pump to
be operated economically, the air intake temperature should not
fall below 15 °C. If the air intake temperature falls below 0 °C
±1.5, the heat pump is switched off and the domestic hot water
heating is heated by the standard heating element (1.5 kW).

The electric heating element fulfils four functions:

Supplementary heating

The heat-up time is approximately halved by switching on
the heating element (via the "Heating element" switch, see
Cap. 6.2 on pag. 6) in addition to the heat pump.

Frost protection

If the air temperature falls below 0 °C ±1.5, the electric heat-
ing element switches on automatically and (nominally) heats
the water up to the domestic hot water setpoint temperature
of 60°C.

Emergency heating

In the event of a heat pump fault, the domestic hot water
supply is maintained by the heating element.

Higher water temperature

If the required domestic hot water temperature is higher than
the temperature achievable by the heat pump (approx.
60°C), it can be raised to a max. of 85°C by means of the
heating element.

NOTE

When the domestic hot water temperature reaches 60

 

°C, the heat pump

 

switches off and the domestic hot water is heated solely by the heating

 

element. The factory setting for the heating element controller is 65

 

°C.

2.2 Refrigerant circuit (heat pump 

operating principle)

The refrigerant circuit is a closed system in which the R134a re-
frigerant is the energy source. The finned heat exchanger ex-
tracts heat from the drawn-in air at a low evaporation tempera-
ture, and transfers it to the refrigerant. The vaporous refrigerant
is taken in by a compressor, where it is compressed to a higher
pressure and temperature level before being transported to the
liquefier, where the heat absorbed in the evaporator and part of
the compressing energy is transferred to the water. Subse-
quently, the high condensation pressure is lowered to the evapo-
ration pressure by a throttle mechanism (expansion valve), and
the refrigerant can again extract heat from the intake air in the
evaporator.

2.3 Safety and control devices

The domestic hot water heat pump is equipped with the following
safety devices:

High pressure switch (HP)

The high pressure switch protects the heat pump against unac-
ceptably high operating pressure in the refrigerant circuit and
switches the heat pump off in the event of a fault. The heat pump
restarts automatically as soon as the pressure in the refrigerant
circuit has dropped again.

Safety temperature limiter for heating element 

(STL)

The STL protects the domestic hot water system against unac-
ceptable temperature increases.
The heating element is disconnected all-pole if the set switching
value (99 °C) is exceeded.
The heating element cannot be switched on again until the do-
mestic hot water temperature has decreased to 

90°C and the

reset button (see illustration) on the STL is pressed (this must
only be done by qualified personnel).

The domestic hot water heat pump is also equipped with the fol-
lowing regulation and control devices:

3DUWLWLRQ

&RQWUROSDQHO

5HVHWEXWWRQ

ƒ

ƒ

%

67%

Содержание HPWH 300

Страница 1: ...HPWH 300 HPWH 300HE Hot Water Heat Pump for Outdoor Installation English Installation and Operating Instructions FD 9501...

Страница 2: ...N 4 4 Installation EN 5 4 1 Installation location EN 5 4 2 Installation EN 5 5 Assembly EN 5 5 1 Connecting the water pipes EN 5 5 2 Connecting the condensate hose EN 6 5 3 Electrical connection EN 6...

Страница 3: ...ealand a TEMPER ING VALVE must be fitted by the installer The following are not permitted It is not permissible to operate the device The refrigerating system meets the requirements of ISO 5149 3 2014...

Страница 4: ...mestic hot water temperature is higher than the temperature achievable by the heat pump approx 60 C it can be raised to a max of 85 C by means of the heating element NOTE When the domestic hot water t...

Страница 5: ...ts the evaporator from freezing 3 Storage and transport 3 1 General The domestic hot water heat pump should always be stored and transported packaged in an upright position without being filled with w...

Страница 6: ...e must be provided as shut off facility to avoid unnecessary energy losses Circulation is enabled according to use time or requirement control The nominal pipe widths for the on site sanitary installa...

Страница 7: ...If the supply cord is damaged it must be replaced by a special cord or assembly available for the manufacturer or its service agent 6 Commissioning 6 1 Domestic hot water system ATTENTION The domesti...

Страница 8: ...r heat pump possible fan coasting must be considered General The domestic hot water heat pump is virtually maintenance free Furthermore a one off visual inspection for possible leaks in the water syst...

Страница 9: ...4753 part 6 8 Faults troubleshooting for the user ATTENTION Work on the domestic hot water heat pump is to be performed by qualified personnel only Observe accident prevention regulations The heat pum...

Страница 10: ...nection 6 1 Degree of protection IP 24 IP 24 6 2 Connection voltage 1 N PE 230 V 50 Hz 1 N PE 230 V 50 Hz 6 3 Fuse max A C16 C16 6 4 Heat pump power consumption cos A 0 8 0 8 6 5 Supplementary electri...

Страница 11: ...EN 10 451903 66 18 FD 9501 www dimplex com au English HPWH 300 HPWH 300HE...

Страница 12: ...drawing A II 2 Integration Diagram A III 2 1 Process circuit diagram A III 2 2 Legend A III 2 3 Hydraulic integration diagram A IV 2 4 Legend A IV 2 5 Heat Exchanger Integration Diagram for Thermal S...

Страница 13: ...JHU RXWSXW 5 H WHUQDO WKUHDG HDW H FKDQJHU LQSXW 5 H WHUQDO WKUHDG LUFXODWLRQ SLSH 5 H WHUQDO WKUHDG RW ZDWHU RXWOHW FRQQHFWLRQ 5 H WHUQDO WKUHDG RQGHQVDWH KRVH LQQHQ 6HDO YDOYH OHFWULFDO KHDWLQJ HOHP...

Страница 14: ...3 14 15 Compressor Evaporator Hot water cylinder with Liquifier High pressure switch Check valve Air inlet temperature sensor R1 Filter dryer Expansion valve Cylinder temperature sensor Heating elemen...

Страница 15: ...ng line drain line of the valve must not be blocked 8 Circulation pump 9 Outlet No connections for second heat generator required i e no heating water flow and no heating water return flow for hot wat...

Страница 16: ...egration Diagram for Thermal Solar Installation HDW H FKDQJHU HDW H FKDQJHU ORZ 5HWXUQ IORZ KHFN YDOYH 7DS 7KHUPRPHWHU URP WKH FROOHFWRU 6DIHW YDOYH QWO IWXQJ H DHUDWLRQ 3XUJH 3UHVVXUH JDXJH DWFKPHQW...

Страница 17: ...A VI 451903 66 18 FD 9501 www dimplex com au Appendix HPWH 300 HPWH 300HE 3 Circuit Diagrams 3 1 Last Load...

Страница 18: ...www dimplex com au 451903 66 18 FD 9501 A VII Appendix HPWH 300 HPWH 300HE 3 2 Control...

Страница 19: ...essor F17 Safety temperature limiter E1 H1 Electric heater indicator lamp J1 Digital inputs outputs U 230 V J3 Analogue inputs screw terminals K1 Compressor load relay K2 Starting relay for M1 K4 Load...

Страница 20: ...www dimplex com au 451903 66 18 FD 9501 A IX Appendix HPWH 300 HPWH 300HE...

Страница 21: ...Glen Dimplex Australia Pty Ltd 1 21 Lionel Road Mount Waverley VIC 3149 www dimplex com au ph 1300 556 816 fax 1800 058 900 Subject to alterations and errors...

Отзывы: