www.dimplex.de 452163.66.68 · FD 9705
EN-5
HPL 6S-TU(R)W
English
4 Accessories
4.1 Remote control
A remote display adds convenience and is available as a special
accessory. Operation and menu navigation are identical to those
of the heat pump manager. Connection takes place via an inter-
face (special accessories) with RJ 12 Western plug.
NOTE
In the case of heating controllers with a removable control panel, this can
also be used directly as a remote display.
4.2 Building management system
The heat pump manager can be connected to a building man-
agement system network via supplementation of the relevant in-
terface plug-in card. The supplementary installation instructions
of the interface card must be consulted regarding the exact con-
nection and parameterisation of the interface.
The following network connections can be made on the heat
pump manager:
Modbus
EIB, KNX
Ethernet.
5 Transport
ATTENTION!
When transporting the heat pump, ensure that it is not tilted more than
45° (in any direction).
Transport to the final installation location should be carried out
with a pallet. The basic device can be transported with a lift truck,
hand truck or by means of 3/4" pipes fed through the holes in the
base plate or frame.
6 Installation
6.1 General
The device should always be installed on a permanently smooth,
even and horizontal surface. The entire frame should be in direct
contact with the ground in order to ensure an adequate sound-
proof seal and to prevent the water-bearing components from be-
coming too cold. If this is not the case, additional insulation
measures may be necessary. Furthermore, the heat pump
should be set up so that the air outlet direction of the fan is per-
pendicular to the main wind direction to allow unrestricted de-
frosting of the evaporator. The heat pump is designed for instal-
lation on even ground. In the case of different conditions (e.g.:
installation on a platform or flat roof) or there is a greater risk of
the heat pump tipping over (due to an exposed position or high
wind exposure), additional protection against tipping over must
be provided. The responsibility for the heat pump installation lies
with the specialist system construction company. During the in-
stallation, local requirements such as building regulations, static
load of the building, and wind exposure must be accounted for.
It must be possible to carry out maintenance work without hin-
drance. This is ensured when observing the distances to solid
walls as shown in the figure.
The specified dimensions are valid for stand-alone installation
only.
ATTENTION!
Do not restrict or block the area around the air intake or outlet.
ATTENTION!
Observe country-specific building regulations!
ATTENTION!
For installation close to walls the physical influences of the building must
be considered. No windows or doors should be present in the area
surrounding the air outlet of the ventilator.
ATTENTION!
In cases of installation close to a wall, there may be more sediment in the
air inlet and outlet areas due to the air current. The colder outside air
outlet should discharge in such a way as to not increase the heat losses
in heated neighbouring rooms.
ATTENTION!
Installation in a hollow or in an inner courtyard is not permitted because
cooled air collects at ground level and is drawn in again by the heat pump
during lengthy operation.
Содержание HPL 6S-TURW
Страница 2: ......
Страница 14: ...DE 12 452163 66 68 FD 9705 www dimplex de Deutsch HPL 6S TU R W...
Страница 16: ...DE 14 452163 66 68 FD 9705 www dimplex de Deutsch HPL 6S TU R W...
Страница 28: ...EN 12 452163 66 68 FD 9705 www dimplex de English HPL 6S TU R W...
Страница 40: ...FR 12 452163 66 68 FD 9705 www dimplex de Fran ais HPL 6S TU R W...
Страница 53: ...www dimplex de 452163 66 68 FD 9705 A XIII HPL 6S TU R W Anhang Appendix Annexes...
Страница 54: ...A XIV 452163 66 68 FD 9705 www dimplex de Anhang Appendix Annexes HPL 6S TU R W...
Страница 55: ...www dimplex de 452163 66 68 FD 9705 A XV HPL 6S TU R W Anhang Appendix Annexes...