background image

IMPORTANT

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR

FUTURE REFERENCE. Note also the information presented on the appliance

CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/OR 

DAMAGE AND MAY INVALIDATE YOUR GUARANTEE

IMPORTANT SAFETY ADVICE

When using electrical heaters, basic precautions should always be followed to reduce the risk 

of fire, electrical shock, and injury to persons, including the following:

IMPORTANT – The wall bracket supplied with the heater must be used.

IMPORTANT – All packaging should be disposed of in an appropriate manner.

OVERHEATING WARNING 

WARNING - In order to avoid overheating, do not cover or obstruct the heater. Do not place material 

or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains 

or furniture, as this could cause overheating and a fire risk. NEVER cover or obstruct in any way the 

heat outlet slots at the top of the heater or the air inlet slots in the base of the heater. 
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.  The heater carries a warning 

‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is accidentally 

covered.
CAUTION - Some parts of this product can become very hot and cause burns. Particular 

attention has to be given where children and vulnerable people are present.

For  your  safety  this  heater  is  fitted  with  a  thermal  cut-out.  In  the  event  that  the  product 

overheats for some reason, the cut-out prevents excessive temperatures on the product by 

cutting the power to the heater. Once the heater has cooled down, it will reset automatically, 

it will continue to cycle on and off automatically until the reason for overheating is removed. 

The display screen may flash red to indicate the product has overheated. To reset the display, 

remove the obstruction and hold Enter for 10 seconds.

SUITABLE APPLICATIONS

WARNING - This heater is suitable for normal domestic household purposes and should not 

be used in any other type of environment. This product should only be used in the country 

where it was purchased from by a recognised commercial retailer. Do not use outdoors.

SERVICING AND REPAIRS

WARNING - Servicing and product repairs should only be undertaken by the manufacturers 

approved service agent or a similarly trained or qualified person, using only exact manufacturer 

approved spare parts.

PLEASE NOTE: Household dust, lit cigarettes, candles and oil burners, combined with the 

convection effect of electric heaters can cause significant soot deposits to build up on the 

surface directly above and to the sides of the heater. This is not a fault of the heater. Extensive 

burning of candles or smoking in the operating environment of this product can produce heavy 

discolouration within a few months of use.

OPERATING WARNINGS

IMPORTANT: Remember to observe all safety warnings and precautions when operating the 

heater on the automatic or timer modes, either attended or unattended since a fire risk exists 

when the heater is accidentally covered or displaced.

CAUTION:  Do not use if the heater’s mains power lead is damaged. If the supply cord is 

damaged it must be replaced by the installer or an approved Dimplex service partner.

2

Содержание Girona GFP050E

Страница 1: ...rona GFPE Models GFP050E GFP075E GFP100E GFP150E GFP200E These instructions should be read carefully and retained for future use Note also the information presented on the appliance INSTRUCTION MANUAL...

Страница 2: ...he product by cutting the power to the heater Once the heater has cooled down it will reset automatically it will continue to cycle on and off automatically until the reason for overheating is removed...

Страница 3: ...ectrical connection point Excess cable should not be inserted and stored behind the heater WARNING This heater must not be connected to the electricity supply via an external switching device such as...

Страница 4: ...inal heat output elmax 0 00 0 00 0 00 0 00 0 00 At minimum heat output elmin 0 00 0 00 0 00 0 00 0 00 In standby mode elSB 0 0005 0 0005 0 0005 0 0005 0 0005 With open window detection Yes With adapti...

Страница 5: ...ng with louvered up facing grille Advanced controls with capacitive sense technology for total flexibility of heating Colour Finish Metal Chassis Air Outlet Grille Control Moulding Traffic White RAL 9...

Страница 6: ...de on page 8 if you need a reminder of how to use the basic functions in the future The heater is designed for wall mounting using the wall bracket supplied It should only be operated when in the upri...

Страница 7: ...ittings provided are used for the particular wall type 3 Present the heater to the wall bracket and engage bottom slots in the back with bracket hooks 4 Press heater into locked position and ensure th...

Страница 8: ...rature is above this temperature then the heater will not operate The heater leaves the factory with this temperature set at 21 C which represents a typical comfortable room temperature If you require...

Страница 9: ...rt Off period and you want heat press the Advance button If the heater is in Comfort On and you don t want heat press the Advance button and it will go off until the beginning of the next Comfort On p...

Страница 10: ...5 Enter Button 6 Advance Button 7 Heating Status Operation Manual NOTE Should the heater fail to operate this may be due to the room temperature being higher than the thermostat setting NOTE Your hea...

Страница 11: ...the enabled features The timed periods during which the heater is providing heat are defined as Comfort On this is displayed at the bottom of the screen Outside of heating periods the heater will not...

Страница 12: ...e event of a mains power outage To adjust the time or date follow the steps below Press the Menu button Select Date Time by pressing the Enter button Press and to select the correct day of the month a...

Страница 13: ...d 08 00 until 21 00 3 Holiday pre programmed for 7 days at 10 C set the number of days required from 1 to 300 and the temperature required 7 C is advised if you just want to protect the property from...

Страница 14: ...copy these settings to successive days or all days by either choosing Copy Next or Copy All If preferred each day can be modified individually and saved It is also possible to Clear each day or Clear...

Страница 15: ...be maintained during this period and press the Enter button At the end of the Holiday mode the heater will automatically revert back to the previously selected programme Constant Heat Modes To choose...

Страница 16: ...ost Options The Advance function allows the heating profile of the heater to be changed temporarily When a timer has been selected the Advance function is used to begin the next Comfort On mode early...

Страница 17: ...ackground temperature setting when the product is not in a Timer Mode Comfort On period Open Window detection OW when enabled allows the heater to reduce the target room temperature limiting energy wa...

Страница 18: ...ance will energise to control the room to a desired temperature During a runback period the set point can be adjusted by the user however it is possible to assign a maximum set point limit during the...

Страница 19: ...then set the new PIN code Enabling runback timer mode From the main Runback lock menu select Runback and then Enable using Enter Runback mode will be enabled normal functionality of the appliance wil...

Страница 20: ...ck lock is enabled and the appliance is not in a runback period the appliance maintains a minimum temperature value at all times The user can still activate runback to boost room temperature as normal...

Страница 21: ...wever advisable to keep the room well ventilated Cleaning WARNING ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER Before commencing cleaning isolate the heater from the electrical s...

Страница 22: ...heat escaping through the windows 5 Windows Nearly 25 of heat loss can occur through poorly insulated frames and single glazing If you can t afford to double glaze all your windows go for the rooms yo...

Страница 23: ...call the Helpline on 0344 879 3588 or visit https www gdhv com contact us and complete the online form For ROI please email serviceireland glendimplex com or call 353 0 1 842 833 We will need details...

Страница 24: ...roof of purchase and if required by Dimplex proof of delivery If you are unable to provide this documentation you will be required to pay for any repair work required Any repair work under the Dimplex...

Страница 25: ...SCALE 0 500 Cut Out Auto Reset 125 O Earth Room Sensor PCB Monterey Girona Wiring Diagram Feb 2018 Dashed line White Wire Solid line Black Wire 25...

Страница 26: ...ion GDHV All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Dimplex A division of GDC Group Ltd This product co...

Отзывы: