EN-7
1802/A
www.dimplex.de/en
English
FPE 050E - FPE 200E
9.2 Fixed set heating programs P1 - P3
NOTE
The time blocks for the programs P1 - P3 are fixed and
can not be changed.
One time block (A): A whole hour.
Sun symbol (B): Comfort temperature
Moon symbol (C): Eco temperature
Program P1
Specification of a comfort temperature from 5 am to
9 am and from 5 pm to 11 pm.
Program P2
Specification of a comfort temperature from 5 am to
9 am, from 12 midday to 2 pm and from 5 pm to 11 pm.
Program P3
Specification of a comfort temperature from 5 am to
11 pm.
NOTE
Specific days can be assigned to the programs P1 - P3.
See section 5.3.
9.3 Freely adjustable heating programs
P4
-
P6
NOTE
The programs P4 - P6 can be set individually and can
be changed at any time.
Up to three comfort and three lower times can be
defined for each program.
Press the WINDOW and AUTOMATIC
OPERATION keys simultaneously for three
seconds.
ON or OFF is shown.
Use the + / – keys to switch to ON if necessary.
Confirm with the MANUAL key. Pr is shown.
Press the + / – keys multiple times until program P4
is shown.
Press the MANUAL key. DE1 is shown.
Press the MANUAL key. Hour (H) appears.
Use the + / – keys to set the time for the comfort
temperature.
Press the MANUAL key. A is shown.
Use the + / – keys to set the time for the lower
temperature.
Press the MANUAL key. DE2 is shown.
Set the other comfort and lower times in the same
way. Once all comfort and lower times are set, Pr is
shown.
Press the – key to switch to EXIT.
Press the MANUAL key to return to the main
display.