www.dimplex.eu
2203/A
EN-7
DX 521, DX 522 T
English
5. Overload protector
For your safety, the heating device is equipped with
an overload protector. If the air circulation is inter
-
rupted (e.g. due to the air grille being covered or
closed), the device switches off automatically.
In this case, the power supply to the heating device
should be disconnected for a few minutes (switch off
the fuse) to allow the device to cool down sufficiently.
Before recommissioning the device, remove the rea
-
sons for the overload protector being triggered.
6. Maintenance
The device must be disconnected from the mains and
allowed to cool down before maintenance. Clean the
outside of the device using a soft, damp cloth. Do not
use scouring powder or furniture polish as this may
damage the surface.
Dust which gathers inside the device can be removed
from the outside using a vacuum cleaner.
7. Faults
If the heating device is not emitting any heat, check
the following points:
Has the heating level been selected?
Has the thermostat been set to the desired tem
-
perature?
Has the overload protector been triggered? See
chapter 5.
Is the fuse in the switch box switched on?
If you cannot remedy the fault, please contact your
electrical retailer. The retailer will require the product
number (E no.) and the production date (FD) of the de
-
vice. This information is listed on the type plate.
8. Warranty
This product is supplied with a two-year warranty ac
-
cording to our terms of guarantee.
9. Recycling
Do not dispose of the device with general
household waste. Take the device to the
available collection points at the end of its
service life.
10. Technical data
Order code
Unit
DX 521
DX 522 T
Connection voltage
1/N/PE 230-240 V ~ 50 Hz
Power consumption
kW
2.0
Protection class
I, with protective conductor
Degree of protection
IP20
Heating levels
kW
1.2 / 2.0
Heat output
Nominal heat output
Pnom
kW
2.0
2.0
Minimum heat output (guide value)
Pmin
kW
1.2
1.2
Maximum continuous heat output
Pmax,c
kW
2.0
2.0
Additional power consumption
At nominal heat output
Elmax
kW
0.0
0.0
At minimum heat output
Elmin
kW
0.0
0.0
In standby mode
elSB
kW
0.0
0.0
Type of heat output/room temperature control
Mechanical thermostat for room temperature control
°C
7 - 35
Dimensions (width x height x depth) (with / without feet)
mm
585 x 443 x 233 / 104
Weight
kg
3.75
4.25
Glen Dimplex Deutschland GmbH
Phone: +49 9221 709 700
Am Goldenen Feld 18
Fax: +49 9221 709 701
95326 Kulmbach
E-mail: