9
Fireplace Installation
Option #3
- Hardwire
Wire a dedicated, properly
1.
fused circuit with 120 Volt,
15 Amp rating. Allow up to
eight (8) feet of service cable
for connecting power supply
to junction box on fireplace
when installing after finishing
wall.
CAUTION:
Use two
conductor, non-metallic sheath
cable with ground wire (3 wires
total) for the incoming power
supply on fireplace inserts. use
appropriate wire to meet local and
national electrical codes for rated
power consumption.
remove the outer jacket and
2.
strip the individual conductor
from the end.
Loosen the screw securing
3.
the junction box cover and
remove the cover.
Take the cables out from the
4.
junction box, loosen the two
wire twist nuts and remove
the cord set (Figure 2).
Route the power supply wire
5.
through the knockout on
supplied alternative junction
box cover and secure with
a wire clamp (not supplied)
(Figure 3).
Connect the black wire (live)
6.
from the unit to the black wire
from power supply (Figure 3).
Connect the white wire
7.
(neutral) from the unit to the
white wire from power supply
(Figure 3).
Connect the green wire
8.
(ground) from the unit to the
green wire from power supply
(Figure 3).
Figure 2
Figure 3