13

  Maintenance

Light Bulb Replacement

Allow at least five (5) minutes for 

light bulbs to cool before touching 

bulbs to avoid accidental burning 

of skin.
Light bulbs need to be replaced 

when you notice a dark section 

of the flame or when the clarity 

and detail of the log ember bed 

exterior disappears.  There are 

two (2) bulbs under the log set, 

which generate the flames and 

embers.

Light Bulb Requirements

Quantity of two (2) clear 

chandelier or candelabra bulbs 

with an E-12 (small) socket base, 

60 Watt rating.  Example: GE 

60BC or Philips 60 CTC.

Do not exceed 60 Watts per 

bulb.

Helpful Hints

It is a good idea to replace both 

light bulbs at one time if they are 

close to the end of their rated life.  

Group replacement will reduce 

the number of times you need 

to open the unit to replace light 

bulbs.  Care must be taken when 

removing the log set.  

To Access The Lower Light 

Bulb Area: 

(Figure 6)

remove front glass assembly.

1. 

Pull the back edge of the 

2. 

plastic ember bed forward 

until the rear tab releases 

from the ledge located at 

the bottom of the partially 

reflective glass.

!

IMPORTANT:  

Only handle the 

log set by the ember bed.

!

NOTE:  

Log set fits tightly 

into firebox, some force may be 

necessary to remove.

Set log set in front of 

3. 

fireplace.
Disconnect flicker from motor 

4. 

(see Figure 6).
unscrew bulbs counter 

5. 

clockwise.
Insert new bulbs.

6. 

reconnect flicker to motor.

7. 

Figure 6

Flicker

Содержание DF2550

Страница 1: ...manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property...

Страница 2: ...CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment Warning Procedures and techniques which if not carefully followed will expose the user to the r...

Страница 3: ...void the warranty Please record your model and serial numbers below for future reference model and serial numbers can be found on the Model and Serial Number Label of your fireplace NO NEED TO RETURN...

Страница 4: ...ireplace has been dropped or damaged in any manner Return heater to authorized service facility for examination electrical or Important Instructions mechanical adjustment or repair Do not use outdoors...

Страница 5: ...the use of an extension cord Extension cords may overheat and cause a risk of fire If you must use an extension cord the cord must be No 14 AWG minimum size and rated no less than 1875 Watts Do not b...

Страница 6: ...r television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or reloca...

Страница 7: ...d other applicable regulations to reduce the risk of fire electric shock and injury to persons Do not attempt to wire your own new outlets or circuits To reduce the risk of fire electric shock or inju...

Страница 8: ...nternal opening dimensions Figure 1 New Wall Construction Select a suitable location that 1 is not susceptible to moisture and is away from drapes furniture and high traffic Place the fireplace in the...

Страница 9: ...the outer jacket and 2 strip the individual conductor from the end Loosen the screw securing 3 the junction box cover and remove the cover Take the cables out from the 4 junction box loosen the two w...

Страница 10: ...rance for air circulation beneath the fireplace insert is provided by two 2 rubber feet CAUTION Do not install the fireplace directly on carpet or similar surfaces which may restrict air circulation N...

Страница 11: ...switching the Main ON OFF switch to OFF and waiting five 5 minutes before switching the unit back on CAUTION If you need to continuously reset the heater disconnect power and call Dimplex customer se...

Страница 12: ...and then place the Main ON OFF Switch in the Figure 5 Off Button On Button Battery Battery Cover Operation Remote Control position Within 3 10 seconds of changing the switch position press the ON butt...

Страница 13: ...is a good idea to replace both light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the number of times you need to open the unit to replace light bul...

Страница 14: ...y operation During shipment installation handling etc the front glass may collect dust particles these can be removed by dusting lightly with a clean dry cloth To remove fingerprints or other marks th...

Страница 15: ...arranty Dimplex Warranty warrants such products to be free from defects in material and workmanship for a period of 2 years from the date of the first purchase of such products as follows a a repair o...

Страница 16: ...ment is not commercially practicable or cannot be timely made Dimplex may in lieu of repair or replacement choose to refund the purchase price for such product or part This limited warranty entitles t...

Страница 17: ...est and expense at Dimplex s then current rates for such services What Dimplex and its dealers and service agents are also not responsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGE...

Страница 18: ...ition Switch 2800071100RP Terminal Block 4000080100RP Power Cord 4100040300RP Partially Reflective Glass 5901410200RP Control Knob 8801080100RP Stainless Steel Trim Assembly 1020230280RP Gloss Black T...

Отзывы: