Saving energy
Set the desired warm water temperature directly on the
■
flow-through heater.
Mixing with cold water at the armature for water that is too
hot consumes unnecessarily water and energy.
At approx. 40 °C (temperature selection position
) the
unit operates most economically.
Cleaning
Simply wipe the appliance with a damp cloth.
Do not use intensive or abrasive cleaning agents.
A fault, what to do?
If your appliance does not operate as required, it is often due to a very minor problem. Please check whether you can remedy
the fault yourself by using the following guidelines. You will save yourself the costs of an unnecessary visit by customer service
personnel.
Fault
Cause
Solution
Who
Water flow-rate is too low.
The filter in either the water tap or
the showerhead is clogged
Remove the filter and either
clean it or descale it.
Customer
The filter in the corner regulating
valve is clogged.
Get a servicing expert to clean the
filter.
Servicing
expert
The filter upstream from the check
valve in the cold water supply inlet
is clogged.
Remove the filter and either
clean it or descale it.
Servicing
expert
The desired water temperature is
not reached.
The continuous-flow heater is
connected to a thermostatically-
controlled water tap.
Set the temperature on the continu-
ous-flow heater to “max”.
Customer
The power limit has been reached.
Water flow-rate is too high and/or
the cold water supply temperature
is too low.
Reduce the flow-rate at the water
tap supply.
Customer
By a qualified professional:
use the angle valve to regulate the
flow-rate.
Check the flow-rate limiter or re-
place it with a smaller one.
Servicing
expert
The water is not sufficiently warm.
The fuse in the house electrical in-
stallation has tripped/blown.
Check the fuse in the house electri-
cal installation.
Customer
The appliance‘s automatic circuit
breaker has been tripped.
Get the appliance‘s automatic cir-
cuit breaker checked by an electri-
cian. Check the permissible supply
temperature.
Servicing
expert
The power limit has been reached.
Water flow-rate is too high and/or
the cold water supply temperature
is too low.
By a qualified professional:
use the angle valve to regulate the
flow-rate.
Check the flow-rate limiter or re-
place it with a smaller one.
Servicing
expert
From time to time, cold water
flows out.
The air sensor in the appliance de-
tects air in the water and momen-
tarily switches the heating element
off.
After a few seconds, the continu-
ous-flow heater automatically goes
back into operation.
Continu-
ous-flow
heater au-
tomatically
resolves
problem
Winter operation:
The desired water temperature
leaving the tap is no longer
reached.
The supply temperature has
reduced.
Reduce the water flow on the taps
until the desired water temperature
is reached.
Customer
Содержание DEE 1803
Страница 7: ...7 DE...
Страница 13: ...13 EN...
Страница 17: ......
Страница 18: ...I 1 3 2 4 4 5 100 1 3 2 388 ca 96 70 44 100 ca 72 332 max 17mm max 31mm ca 2mm ca 16mm 3 4 2 1 III II...
Страница 19: ...ca 72 388 ca 96 70 44 100 332 8 b c 7 b c 6 a b c 5 4B 4A 2 3 hot cold 100 1 A B II...
Страница 20: ...III 5 4 1 2 3 max 16 mm B ca 2 mm A 2A 2B a 3 1...
Страница 22: ...V 3 4 1 2 VI 3 4 6 5 min 40 mm min 40 mm 0 mm PEL3L2L1 1 2 RESET L1 L2 L3 PE...
Страница 23: ...A 1 2 3 4 1 2 3 E L 3 L 2 L 1 3 2 1 PE PE B LED D C...
Страница 24: ......
Страница 27: ...19 FR...
Страница 33: ...25 NL...