19.  Remove  the  convector  circuit  mains  block  and  insulation  card  from 
the left side of the base panel. Unclip the wires running across the heater 
below the inner front.

20. Remove screws retaining front inner skin.

21. Carefully lift the bottom of the front inner skin panel out of the retaining 
! ange at the base of the heater, taking care not to damage the insulation, 
hydraulic  thermostat  probe,  heating  elements  and  other  vulnerable 
components attached to this panel.

22. Remove the internal packing by sliding it up and off the elements, taking 
care not to damage the insulation.

23. Remove one element to allow access for the back row of bricks. On the 
CXL24N/CXLS24N remove the element to right of centre, on the CXL18N/
CXLS18N  remove  the  central  element  and  on  the  CXL12N/CXLS12N 
remove the left hand element. Loosen the two screws securing the element 
tails in the ceramic block, and lift the element up and out of the heater.

24.  Position  the  bottom  rear  layer  of  bricks  with  the  airway  restrictions 
coincident with the air slots in the base insulation slab. Push the bricks 
" rmly  to  the  back  of  the  heater.  Fit  the  top  rear  row  of  bricks,  with  the 
airway restrictions uppermost.

Содержание CXLS24

Страница 1: ...e heater Only heat resisting cable minimum rating T85 should be used If used in a bathroom the heater must be installed such that switches and other controls cannot be touched by a person in the bath...

Страница 2: ...each end packaging piece Stand heater on its feet and remove all packaging pieces 5 Position heater against wall in intended nal position taking note of the minimum xing dimensions given below If tted...

Страница 3: ...than the length of the plastic insert so that the xing is made below the plaster layer 12 Low Density Block Walls A specialised xing such as the Uni x LB70 should be employed following closely the ma...

Страница 4: ...the following must be strictly adhered to a For skirtings higher than 100mm 4 it will be necessary to position the heater with the screws attached through the alternative xing slots to the front b Fo...

Страница 5: ...l packing by sliding it up and off the elements taking care not to damage the insulation 23 Remove one element to allow access for the back row of bricks On the CXL24N CXLS24N remove the element to ri...

Страница 6: ...n 20 are replaced securely 29 Replace the spacer nut washer and screw removed in 18 and reconnect the two quick connect terminals removed in 19 30 Connect the off peak supply to the storage terminal b...

Страница 7: ...ircuit 900W 1450W 2000W Note if the heater is situated underneath a shelf or overhand up to 250mm high then the brown wire should remain in circuit 33 Holding the bottom edge if the front panel toward...

Страница 8: ...AIR SENSING STAT Peak Circuit Diagram CXL24N CXLS24N BROWN BROWN CUT OUT MAUVE BLUE BLUE BLUE BROWN MAUVE BROWN CONVECTOR ELEMENT CONVECTOR ELEMENT ELEMENT SELECTOR BLOCK MAINS BLOCK L SWITCH NEON AI...

Отзывы: