Dimplex Creme RTOPSTV20GC Скачать руководство пользователя страница 5

Maintenance

GENERAL TIPS

Only use filtered tap water in this appliance.

Always ensure that the appliance is sitting on a level surface.

If you intend not using the appliance for longer than 2 weeks, remove and empty the sump and water tank.

Once installed, never move this appliance or lay on its back, without draining the water from sump and water tank.

The appliance should never be operated if the lamps are not working.

The lamps should be regularly inspected as described under ‘Changing lamps’.

FILLING THE WATER TANK

When the water tank is empty, the flame and smoke effect shuts off and you will hear 2 audible beeps, follow these 

steps.

1. Press Switch ‘A’ to 

(0)

 (See Fig.10)

2. Gently lift out the fuelbed and carefully set aside.

3. Remove the water tank by lifting upwards and outwards.

4. Place the water tank in sink and remove cap, Anti-clockwise to open. (Fig 7)

5. Fill tank with 

filtered tap water only

. This is necessary to prolong the life of the flame and smoke producing unit.

The water should be filtered through a conventional domestic water filter unit and the filter should be replaced 

regularly.

6. Screw the cap back on, do not over tighten.

7. Return the tank to the sump, with the tank cap facing down and the flat side of the tank facing outward. (Fig 8)

8. Gently place the fuelbed back into position. (Fig 9)

9. Press Switch ‘A’ to ‘ON’ 

(I)

 position (See Fig.10)

CHANGING LAMPS

If the flame and smoke effect appears grey or colourless it may be that one or more lamps have failed.

You can check for lamp failure as follows.

1. Leaving the flame effect on, lift out the fuelbed and water tank.

2. It should be possible to view the lamps with the nozzle in place and observe which one needs to be changed.

3. Put Switch ‘A’ in the ‘OFF’ position, and unplug the fire from the mains.

4. Leave the appliance for 20 minutes to allow the lamps to cool down before removing them.

5. Remove the sump as described in the Cleaning Section.

6. Remove the defective lamp, by gently lifting vertically and disengaging the pins from the lamp holder, (See Fig.4 

and 4a).

Replace with a Dimplex OPTIMYST, 12V, 45W, Gu5.3 base, 8º beam angle, coloured lamp. (Purchased from our 

website http://spares.dimplex.co.uk)

7. Carefully insert the two pins of the new lamp into the two holes in the lamp holder. Push firmly in place. (See Fig.4 

and 4a).

8. Replace the sump, nozzle, water tank and fuelbed.

CLEANING

Warning

 – Always press Switch ‘A’ to the ‘OFF’ 

(0)

 position (See Fig.10) and disconnect from the power supply before 

cleaning the fire.

We recommend cleaning the following components once every 2 weeks, particularly in hard water areas:-

Water Tank, Sump, Nozzle, Tank cap and seal, Air filter.

For general cleaning use a soft clean duster – never use abrasive cleaners. 

To remove any accumulation of dust or fluff the soft brush attachment of a vacuum cleaner should occasionally be 

used to clean the outlet grille of the fan heater.

Water tank

1. Remove water tank, as described earlier, put into sink and empty water.

2. Using the supplied brush gently rub the inside surfaces of the cap paying particular attention to the rubber ring in

the outer groove and the centre rubber seal.

3. Put a small quantity of washing up liquid into the tank, refit the cap and shake well, rinse out until all traces of 

washing up liquid are gone.

4. Refill with filtered tap water only, replace the cap, do not overtighten.

Sump

1. Press Switch ‘A’ to the ‘OFF’ 

(0)

 position

2. Gently lift out the fuelbed and place carefully on the ground.

3. Remove the water tank by lifting upwards.

4. Disconnect the electrical connector, located on the right side of the sump. (See Fig.5) .

Содержание Creme RTOPSTV20GC

Страница 1: ...2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC 08 52687 0 Issue 0...

Страница 2: ...ey have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance...

Страница 3: ...o red tabs by turning them by 90 degrees see Fig 2 2 Lift out the Sump Nozzle Fig 3 3 Insert lamps into lamp holders Fig 4 carefully locating the pins into the holes Fig 4a 4 Push lamps firmly into pl...

Страница 4: ...ot been blocked off effectively If the cut out operates unplug the heater from the socket outlet and allow approximately 10 minutes before reconnecting Before switching the heater back on remove any o...

Страница 5: ...changed 3 Put Switch A in the OFF position and unplug the fire from the mains 4 Leave the appliance for 20 minutes to allow the lamps to cool down before removing them 5 Remove the sump as described...

Страница 6: ...ir Consumable parts such as fuses in plugs and bulbs which require routine replacement are excluded from the guarantee Your rights under this guarantee are additional to your statutory rights which in...

Страница 7: ...e flame effect has too much smoke Flame effect setting is too high Turn the flame effect Control knob D to the right about a turn at a time Give the flame generator some time to adjust to the new sett...