7
Fig. 3
Model
A
(mm)
B
(mm)
C
(mm)
BPH100M
418
1073
271
BPH100G
430
1100
265
C (min)
A
150
mm (min)
150
mm (min)
B
Fig. 4
300
mm
300
mm (min)
114
mm
Shelf / Ceiling / Obstruction
Minimum front clearance
To mount the heater to the wall:
1. Remove wall mounting bracket from the back
of the heater by depressing the spring latch
at the side of each bracket - see
Fig.2
.
2. Fix the wall bracket securely to the wall through
the four screw holes. Ensure suitable screw
fi ttings are used for the particular wall type.
3. Present the heater to the wall bracket, and
engage left hand slots in the back with bracket
hooks.
4. Press heater into locked position and ensure
the clips on the right hand side are engaged.
NOTE:
Maximum hanging weight should not exceed
3kg per rail. The rail should not be used for
any other purpose e.g. mobility aid.
WARNING:
This product is heavy and care should be
taken in installation
Minimum mounting clearance
*Please note correct product orientation is
with controller facing right side only
To mount the towel rail:
The heater is supplied with two towel rails. There
are 4 possible towel rail mounting locations on
the heater indicated by screw holes and guides,
as shown in
Fig.1
. The towel rail(s) should be
fi tted prior to mounting the heater on the wall,
using the 4 screws supplied for each rail.
1. Remove protective plastic sleeving from
the rail.
2. With the heater detached from the wall,
position the towel rail in the desired location
by sliding over the top or bottom of the heater.
3. Fix the rail in position using 4 screws provided.