PREPARATION FOR SERVICE

!

 NOTE:

 All components are replaceable from the front of 

the fireplace while the unit is mounted on the wall, with the 

exception of replacement of the power cord.

!

 NOTE: 

If the power cord needs replacing or if the unit 

needs to be removed from the wall for any other reason 

please begin service by following the “PREPARATION FOR 

SERVICE” instructions, then move on to the section “IN

-

STRUCTIONS FOR REMOVING FROM WALL”.

Tools Required:

  Philips head screwdriver 

  

WARNING:

  Disconnect power before attempting any 

maintenance or cleaning to reduce the risk of electric 

shock or damage to persons.  

 CAUTION: 

If unit was operating prior to servicing allow 

at least 10 minutes for lights and heating elements to cool 

off to avoid accidental burning of skin.
1.  Disconnect power source. 

•  Unplug the fireplace from the outlet. 
• 

If unit has been hardwired for power or outlet is not 

accessible from the front, turn the breaker off at the 

electrical panel. 

2.  Remove the front glass assembly by removing the 2 

screws (1 on the left and 1 on the right side).  These 

screws secure the front glass panel to the inside of the 

fireplace. (Figure 4)

3.  Lift the front glass assembly off of the 4 mounts located 

between the outer and inner casing of the fireplace: 2 

on the left and 2 on the right. (Figure 3)  Carefully place 

the glass assembly aside in a safe location.

4.  Proceed to the instructions within this manual relating 

to the repair being performed - see Table of Contents 

for page number.

INSTRUCTIONS FOR REMOVING FROM 

WALL

  

WARNING:

  Disconnect power before attempting any 

maintenance or cleaning to reduce the risk of electric 

shock or damage to persons.  

 CAUTION: 

If unit was operating prior to servicing allow 

at least 10 minutes for lights and heating elements to cool 

off to avoid accidental burning of skin.

!

 NOTE: 

Only required for replacement of the power cord 

or removal from service. 

  CAUTION: 

Follow “Preparation for Service” instructions 

before proceeding.

Mounting - The fireplace may be mounted in one of 3 meth

-

ods:  

• 

Surface Mount

• 

Recess Mount - Partial In-Wall

•  Flush Mount (completely in the wall)

Identify the type of mounting and follow the appropriate 

instructions in the following pages.

  

CAUTION: 

 To prevent injury or damage, turn off the 

breaker in your electrical panel prior to attempting to re-

move this unit off the wall.  

!

 NOTE:

 If fireplace is hard wired directly to the electrical 

panel, and there is not enough slack in the wires within the 

wall to reach your work area, remove the electrical junc-

tion box cover located on the bottom right by removing the 

1 screw on the front of the cover.  Lift the cover off and set 

aside. Disconnect the 3 wire connectors connected to the 

power source, taking note of their original configuration. 

Surface Mount

(Figure 6)

Tools Required:

  Philips head screwdriver

  CAUTION: 

Follow “Preparation for Service” instructions 

before proceeding.
1.  Remove the decorative glass ember-bed pieces from 

the media tray, which lies along the bottom of the interi-

or Partially Reflective Glass.  A medium sized container 

such as a bucket or a box will be needed to keep the 

glass ember-bed pieces together.

2.  On the bottom of the unit remove the securing screw 

from the L-bracket. (Figure 5)

3.  Lift the unit up and off of the wall. 
4. 

Carefully lay the unit down on a solid flat surface with 

the front of the unit facing up.   

!

 NOTE: 

 If the surface you are using as a work area on is 

a finished surface that is prone to scratches (i.e. hardwood 

flooring), it is recommended that a protective barrier be 

used underneath, (i.e. cloth, cardboard, thick plastic).

Figure 4

Tab

Figure 3

Hooks (4)

Mounts (4)

Front tray

Front glass 

assembly

Содержание BLF34

Страница 1: ...America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 24 Jan 14 IMPORTANT SAFETY INFORMATION Always read this ma...

Страница 2: ...injury or death OPERATION 3 MAINTENANCE 4 EXPLODED PARTS DIAGRAM 5 WIRING DIAGRAM 6 PREPARATION FOR SERVICE 7 INSTRUCTIONS FOR REMOVING FROM WALL 7 Surface Mount 7 Recessed Mount Partial In wall 8 Fl...

Страница 3: ...ery Replacement To replace the battery 1 Slide battery cover open on the remote control Figure 2 2 Install one 1 12 Volt A23 battery in the battery holder 3 Close the battery cover Battery must be rec...

Страница 4: ...tory dur ing the assembly operation During shipment installation handling etc the partially reflective glass may collect dust particles these can be removed by dusting lightly with a clean dry cloth T...

Страница 5: ...RP 6 Flicker Motor 2000220100RP 7 Flicker Assembly 5902720100RP 8 Cutout 2300201500RP 9 LED Light Panel 3000830100RP 10 Remote Receiver 3000821000RP 11 Switch Board 3000821100RP 12 LED Driver Board 30...

Страница 6: ...6 www dimplex com WIRING DIAGRAM M M RL1 RL2 RL3 N N N N L1 120V 60Hz LED CONTROL BOARD LED LIGHTS...

Страница 7: ...minutes for lights and heating elements to cool off to avoid accidental burning of skin NOTE Only required for replacement of the power cord or removal from service CAUTION Follow Preparation for Ser...

Страница 8: ...of the opening by slightly lift ing and pulling forward 4 Carefully lay the unit down on a solid flat surface with the front of the unit facing up NOTE If the surface you are using as a work area is a...

Страница 9: ...ower before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons CAUTION If unit was operating prior to servicing allow at least 10 minutes for lights and h...

Страница 10: ...the switchboard in its original configuration 8 Reassemble in the reverse order as above REMOTE CONTROL RECEIVER REPLACEMENT WARNING Disconnect power before attempting any maintenance or cleaning to...

Страница 11: ...Remove the 2 retaining screws Figure 12 on the bracket that the flicker motor is mounted to remove the assembly 5 Carefully remove the entire assembly NOTE It may be easier to remove the flicker rod...

Страница 12: ...the left and right side of the Partially Reflective Glass Figure 14 3 Remove the 2 screws that secure the controls assem bly Figure 9 located at the top of the mirror on the right side of the unit 4...

Страница 13: ...ions before proceeding 1 Remove the decorative glass ember bed pieces from the media tray which lies along the bottom of the interi or Partially Reflective Glass A medium sized container such as a buc...

Страница 14: ...the assembly is removed care fully ensuring that no wires are caught or over strained 5 Remove the Partially Reflective Glass Carefully place the glass assembly aside in a safe location 6 Remove the h...

Страница 15: ...he heater is on Defective power cord Replace power cord if cord gets too hot to touch Appearance Fireplace does not turn on Manu ally Improper operation Refer to Operation Section No incoming power fr...

Страница 16: ...ion Defective Heating Element Replace Heating Element Heater fan turns on but heater lacks heat Improper operation Refer to Operation Section Loose wiring Trace wiring in unit Defective Heating Elemen...