Ascari - 12kW -
page 12 -
3.1.2 - Number and cross-section of connectors
Example: Cord type U1000, loose in open air rack, ambient temperature 20°C, lenght 15 m.
IMPORTANT
Follow local existing regulations regarding electric connections
Electric connections to mains must be installed according to local and national regulations, which generally
specify:
•
Type of connectors :
-
Type of slipcover
-
Number and cross-section of wires,
-
etc...
•
Type of installation :
-
Magnetic interferences inside bundles,
-
Ambient temperature,
-
Open or covered wires,
-
Length of cords,
-
etc...
Ph = Phase = 16²
N = Neutral = 16²
ASCARI 12
12 kW
2 x 16² + T *
MINIMUM cross-section for each connector in mm²
and number of connectors for above example
Maximum
output P1
Boiler
230 V mono
3.1.1 - Electric datas
3.1- Electric flow rate, number and cross-section of the power
connectors, fuse protection
Amperes for each phase
230 V mono
ASCARI 12
12 kW
52 A
Maximum output P1
Boiler