background image

08/19239/4 - Issue 7

AC3CN Recessed Ceiling Heater / Over Door Heater

The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and 

EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC

0.250

SCALE  

Содержание AC3CN

Страница 1: ...eater The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and 2004 108 EC 0 250 SCALE ...

Страница 2: ...less continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not pl...

Страница 3: ... any flammable materials or sprays in the vicinity of the heater FIRE HAZARD DO NOT insert any foreign objects into the heater openings Risk of injury electric shock or damage to the heater may occur Ensure proper manual handling procedures are observed at all times ATTENTION IN ORDER TO AVOID OVERHEATING DO NOT COVER ...

Страница 4: ... screwdriver or other suitable tool Open the grill and feed the appropriate cable through the cable gland see Y in Fig 2 WARNING Ensure power cable path does not come into contact with internal heater elements or fans Make connections as per wiring Diagram see Fig 3 and close the grille Connection of Switch Panel The mains electrical supply cable and power cable to this heater neither supplied sho...

Страница 5: ...d into the M8 threaded inserts located in the top side of the heater see Fig 1 for dimensions Adjust the height of the heater so the inner edge of the grill surround is flush with the ceiling Installation in a Bulk Head over doorway A hole 579x271mm as indicated in Fig 7 must be cut into the ceiling part of the bulk head Drop rods should be used to mount the appliance in such a position as to have ...

Страница 6: ...ed off and an engineer called Maintenance WARNING ALWAYS DISCONNECT HEATER FROM THE POWER SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE The heater should be serviced annually Any dust or debris should be removed from the grille and elements taking care not to damage the elements Cleaning the Heater Switch Panel External and grille appearance can be maintained by occasionally vacuuming and wiping with a...

Страница 7: ......

Страница 8: ... 879 3587 FAX 0844 879 3582 WEBSITE www dimplex co uk Republic of Ireland Tel 01 8424833 GDC Group Ltd All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Dimplex A division of GDC Group Ltd ...

Отзывы: