Dimplex 6908760100 Скачать руководство пользователя страница 9

 

9

A

B

C

D

E

F

G

40 in (1020 mm)

RECOMMENDED

6 in (152 mm)

MINIMUM

Figure 2

Figure 3

 

Fireplace Installation 

 CAUTION:

 

+

igh temperature

 

keep ele

F

tri

F

al 

F

ords

 drapery

 

and other furnishings at least 
3 feet (0

9m) from the front of 

the heater and away from the 
side and rear

3

 The 

¿

repla

F

e must be 

mounted at a minimum of 
two (2) points

 one of whi

F

must be on a wall stud

 

Some available hanging 

F

ombinations are A-G

 B-F

 

B-G

 C-G

 A-F

 A-E

 A-D and 

Wall an

F

hor

S

F

rew

Wall 
bra

F

ket

Figure 4

D-G

 (Figure 3)

!

 

NOTE: 

Wall an

F

hors must 

be installed in the appropriate 
wall lo

F

ations to fasten the wall 

bra

F

ket to drywall

 (Figure 4) 

4

 

+

old the wall hanging bra

F

ket 

on the wall and mark the 
lo

F

ation of O

1

E (1) of the 

se

F

uring holes

5

 Pla

F

e the bubble level onto 

the top of the wall hanging 
bra

F

ket

6

  Adjust the wall hanging 

bra

F

ket so the bubble on the 

level is 

F

entered between the 

two bla

F

k lines

7

  Mark the two (2) s

F

rew 

lo

F

ations

 on the wall

 

ensuring that the wall bra

F

ket 

stays level

8

  Install the supplied wall 

an

F

hors on the drywall 

marked lo

F

ations by pla

F

ing 

Содержание 6908760100

Страница 1: ...WKLV PDQXDl UVW EeIoUe DWWePSWLQJ Wo LQVWDll oU XVe WKLV UeSlDFe oU oXU VDIeW DlZD V FoPSl ZLWK Dll ZDUQLQJV DQd VDIeW LQVWUXFWLoQV FoQWDLQed LQ WKLV PDQXDl Wo SUeYeQW SeUVoQDl LQMXU oU SUoSeUW dDPDJe...

Страница 2: ...teFhniTueV ZhiFh iI not FareIull IolloZed Zill reVult in damage to the eTuipment WARNING 3roFedureV and teFhniTueV ZhiFh iI not FareIull IolloZed Zill e poVe the uVer to the riVN oI re VeriouV inMur...

Страница 3: ...the Zarranty 3lease reFord your model and serial numEers EeloZ Ior Iuture reIerenFe model and serial numEers Fan Ee Iound on the Model and 6erial 1umEer aEel oI your replaFe NO NEED TO RETURN TO THE...

Страница 4: ...be replaFed by the manufaFturer or its serviFe agent or a quali ed person in order to avoid a ha ard IMPORTANT INSTRUCTIONS Do not operate any unit with a damaged Ford or plug or if the heater has ma...

Страница 5: ...l ny other use not reFommended by the manufaFturer may Fause re eleFtriF shoFN or inMury to persons lways plug heaters direFtly into a wall outlet reFeptaFle 1ever use with an extension Ford or reloFa...

Страница 6: ...ion between the equipment and the reFeiver onneFt the equipment into an outlet on a FirFuit different from that to whiFh the reFeiver is FonneFted onsult the dealer or an experienFed radio T9 teFhniFi...

Страница 7: ...breaNer trips or the fuse blows on a regular basis when the heater is operating dditional applianFes on the same FirFuit may exFeed the Furrent rating of the FirFuit breaNer WARNING nsure the power Fo...

Страница 8: ...pplied Drill and drill bits as required Approximate time 30 minutes for installation 1 Remove the two sFrews that seFure the hanging braFket to the baFk of the rebox igure 1 2 6eleFt an appropriate lo...

Страница 9: ...F A E A D and Wall anFhor SFrew Wall braFket Figure 4 D G Figure 3 NOTE Wall anFhors must be installed in the appropriate wall loFations to fasten the wall braFket to drywall Figure 4 4 old the wall h...

Страница 10: ...the sFrews must be installed into a wall stud 12 Mount the unit on the wall so that the tabs on the wall braFket have been inserted into the slots on the baFk of Figure 5 the rebox Figure 5 13 ExFess...

Страница 11: ...used underneath the unit to ensure that the front of the frame does not get sFratFhed 3 Remove the 4 sFrews on eaFh side that seFure the trim to the rebox 4 ift the rebox direFtly up off of the trim...

Страница 12: ...he Temperature Cutoff Switch Should the heater overheat an automatiF Fut out will turn the replaFe off and it will not Fome baFk on without being reset It Fan be reset by switFhing the 3 Position Swit...

Страница 13: ...Figure 9A in the Off O position 2 Wait a minimum of ve 5 seFonds and then plaFe the 3 Position SwitFh in the Remote Control II position 3 Within 10 seFonds of Fhanging the switFh position press the On...

Страница 14: ...s these Fan be removed by dusting lightly with a Flean dry Floth To remove ngerprints or other marks the Partially Re eFtive Glass Fan be Fleaned with a damp Floth The Partially Re eFtive Glass should...

Страница 15: ...rranty Dimplex warrants suFh produFts to be free from defeFts in material and workmanship for a period of 1 year from the date of the rst purFhase of suFh produFts The limited 1 year warranty period a...

Страница 16: ...T IN TORT OR ON ANY OT ER BASIS FOR ANY INDIRECT SPECIA PUNITI9E E EMP ARY CONSEQUENTIA OR INCIDENTA OSS COST OR DAMAGE ARISING OUT OF OR IN CONNECTION WIT T E SA E MAINTENANCE USE OR INABI ITY TO USE...

Страница 17: ...3 Position SwitFh 2800071100RP On Off SwitFh 2800070700RP Remote Control ReFeiver 3000380200RP Remote Control 3000370900RP ED ight Assembly 6908950100RP ED Driver Board 3001170100RP Wall Hanging Kit 1...

Отзывы: