EN-8
2205/A
www.dimplex.eu
English
DFH 22
5. Overload protector
For your safety, the heating device is equipped with
an overload protector. If the permissible temperature
is exceeded, the heating device switches off automat
-
ically.
In this case, the power supply to the heating device
should be disconnected (switch off the fuse) to allow
the device to cool down sufficiently.
Before recommissioning the device, resolve the rea
-
sons (e.g. air grille positioned incorrectly or covered)
for the overload protector being triggered.
If the overload protector is repeatedly triggered, de
-
commission the device and contact your electronics
retailer.
6. Maintenance
The device must be disconnected from the mains and
allowed to cool down before maintenance. Clean the
outside of the device using a soft, damp cloth. Do not
use scouring powder or furniture polish as this may
damage the surface. Dust which gathers inside the
device can be removed from the outside using a vac
-
uum cleaner.
7. Warranty
This product is supplied with a two-year warranty ac
-
cording to our terms of guarantee.
8. Recycling
Do not dispose of the device with general
household waste. Take the device to the
available collection points at the end of its
service life.
9. Technical data
Order code
Unit
DFH 22
Connection voltage
1/N/PE
230-240 V ~
50 Hz
Power consumption
kW
2.0
Protection class
II, without
protective con
-
ductor
Degree of protection
IP21
Heating levels
2
Heat output
Nominal heat output
P
nom
kW
2.0
Minimum heat output
(guide value)
P
min
kW
0.8
Maximum continuous
heat output
P
max,c
kW
2.0
Additional power consumption
At nominal heat output
El
max
kW
0.0
At minimum heat output
El
min
kW
0.0
In standby mode
el
SB
kW
0.0
Type of heat output/room temperature control
Mechanical room temperature
control
°C
5 - 35
Dimensions W x H x D
mm
190 x 230 x 125
Weight
kg
1.12
Glen Dimplex Deutschland GmbH
Phone: +49 9221 709 700
Am Goldenen Feld 18
Fax: +49 9221 709 701
95326 Kulmbach
E-mail: